Omron GRT1-ML2 Hardware Reference Manual page 76

Trajexia motion control system
Hide thumbs Also See for GRT1-ML2:
Table of Contents

Advertisement

Hardware reference
3.5.2
LEDs description
/i
Label
Status
Description
run
off
Start-up test failed. Unit not operational
Operation stopped. Fatal error
on
Start-up test successful. Normal operation
BF
off
Normal operation
on
A fault in the MECHATROLINK-II bus
-
Reserved
3.5.3
TJ1-ML__ connection
The MECHATROLINK-II bus connector (A) fits a MECHATROLINK-II
connector. Use this connector to connect the TJ1-ML__ to a
MECHATROLINK-II network.
The MECHATROLINK-II network must always be closed by the
MECHATROLINK-II terminator.
HARDWARE REFERENCE MANUAL
fig. 30
ML16
RUN