Auxiliary Output Allocations; Using G3Za Multi-Channel Power Controllers - Omron EJ1G User Manual

Modular temperature controllers for gradient temperature control
Hide thumbs Also See for EJ1G:
Table of Contents

Advertisement

Other HFU Functions
5-7-3

Auxiliary Output Allocations

Note
5-7-4

Using G3ZA Multi-channel Power Controllers

The parameters that can be set for auxiliary outputs 1 to 4 are outlined below.
The settable parameters include those for all channels and those for individual
channels.
OUT1
OUT2
Settable
parameters
All channels
Disabled
Temperature Controller Error
All alarm OR
All alarm AND
Alarms 1 to 3 OR
Alarms 1 to 3 AND
Input error OR
Temperature
The Temperature Controller Error output will turn ON when any
Controller Error
bit between bit 0 and bit 13 is ON in the Device A Status. It can
be used to output EJ1G error status.
Refer to Status Lists on page 188 for details on Device A Sta-
tus.
Event inputs 1 to 4 Output the ON/OFF status of event inputs 1 to 4.
Bus inputs 1 to 3
Output the ON/OFF status of bus inputs 1 to 3.
Variable type
F2/B2
Auxiliary Output 1 Assignment
Auxiliary Output 2 Assignment
Auxiliary Output 3 Assignment
Auxiliary Output 4 Assignment
Conditions for use No special conditions.
(1) This parameter can be set only when operation is stopped.
When this parameter has been changed, the new setting becomes effec-
tive the next time a software reset is performed for the Unit or the next
time power is turned ON.
(2) Refer to Parameter List on page 175 for details on parameter settings.
Set the G3ZA settings in the TC4/2 Unit. Refer to 4-5-1 Using G3ZA Multi-
channel Power Controllers for details.
OUT3
OUT2, OUT3, and OUT4 can be set in the same way.
Channel 64
Channel 3
Channel 2
Channel 1
Alarms 1 to 3
All alarms OR
All alarms AND
Input error
Parameter name
(Common) 0 to 2053
(Common) 0 to 2053
(Common) 0 to 2053
(Common) 0 to 2053
Section 5-7
OUT4
Setting range Default
4
5
6
10
123