Programless Communications
5-6-4

Description of Operation

Bits
Value
Read Request
0000: Stop operation Stops operation after a series of operations has been completed.
Bits
0001: Single
0002: Multi
0003: Read setting
Setting Change
0000: Stop operation Stops operation after a series of operations has been completed.
Request Bits
0001: Single
0002: Multi
Operation
0000: Stop operation Stops operation after a series of operations has been completed.
Command
0001: Single
Request Bits
0002: Multi
Note
1,2,3...
108
Set values are read and changed and operation commands are executed by
setting a value in a Request Bits allocated in a PLC memory area.
DM Area
D00000
Read Response Bits
D00001
Setting Change Response Bits
D00002
Operation Command Response Bits
D00500
Read Request Bits
D00501
Setting Change Request Bits
D00502
Operation Command Request Bits
The Request Bits are set to the following values.
Reads the parameters set in the Programless Upload Setting Area once.
Continuously reads the parameters set in the Programless Upload Setting Area.
Reads the parameters set in the Programless Download Setting Area and writes
them to the read area.
Changes only the parameters set in the Programless Download Setting for which
values have been changed.
Continuously repeats the operation of changing only the parameters set in the
Programless Download Setting for which values have been changed.
Executes the operation command set in the Operation Command Code.
Executes the operation command each time the value in the Operation Command
Code changes.
To change the Request Bits, first set the Request Bits to 0000 then change
the setting. The same applies when periodically executing the same operation
command.
Example: Changing a Single Action to a Multi Action
1. For a single action, the Response Bits are set to the single action value,
0001.
Note The Request Bits cannot be changed directly to 0002 because the
setting will not be accepted.
2. Change the Request Bits to 0000, then confirm that the Response Bits
have been set to 0000.
3. Then change the Request Bits to the multi action setting of 0002.
• Each set of Request Bits has a corresponding set of Response Bits. Once
the Request Bits have been set, the Response Bits operate in the order
shown in the following table.
Meaning