Parameter List
Variable
Category Add-
type
ress
E3 (A3)
Can be
Not used.
changed
0100
Alarm 1 Type - CH1
while
stopped.
0101
Alarm 1 Latch - CH1
0102
Alarm 1 Hysteresis - CH1
0103
Alarm 1 Open in Alarm - CH1
0106
Alarm 1 SP Selection - CH1
0107
Alarm 2 Type - CH1
010E Alarm 3 Type - CH1
Not used.
0200
Alarm 1 Type - CH2
4000
Alarm 1 Type - CH64
Note The decimal point position is determined by the sensor selection. With analog inputs, the decimal point
position is determined by the Decimal Point Position B parameter setting. In this case, however, the 0
(****) decimal point position setting will be treated as a setting of 1 (***.*).
Variable
Category Add-
type
ress
E4 (A4)
Can be
Not used.
changed
0101
Heater Burnout 1 Latch
while
stopped.
0102
Heater Burnout 1 Hysteresis
0103
HS Alarm 1 Latch
0104
HS Alarm 1 Hysteresis
Not used.
0201
Heater Burnout 2 Latch
184
Parameter name
H' 00000000: Alarm function OFF (0)
H' 00000001: Upper and lower limit alarm (1)
H' 00000002: Upper limit alarm (2)
H' 00000003: Lower limit alarm (3)
H' 00000004: Upper and lower limit range alarm (4)
H' 00000005: Upper and lower limit alarm with standby
sequence (5)
H' 00000006: Upper limit alarm with standby sequence
(6)
H' 00000007: Lower limit alarm with standby sequence
(7)
H' 00000008: Absolute value upper limit alarm (8)
H' 00000009: Absolute value lower limit alarm (9)
H' 0000000A: Absolute value upper limit alarm with
standby sequence (10)
H' 0000000B: Absolute value lower limit alarm with
standby sequence (11)
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
H' 00000001 to H' 0000270F (1 to 9999)
H' 00000000: Close in alarm (0)
H' 00000001: Open in alarm (1)
H' 00000000: Ramp SP (0)
H' 00000001: Target SP (1)
The rest are the same as Alarm 1.
The rest are the same as channel 1.
Parameter name
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
H' 00000001 to H' 000003E8 (0.1 to 100.0)
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
H' 00000001 to H' 000003E8 (0.1 to 100.0)
The rest are the same as from Heater Burnout 1 Latch to HS Alarm 1 Hysteresis.
Setting (monitor) range
Setting (monitor) range
Appendix
Defau-
Unit
Attribut-
Target Unit
lt
es
TC4/
HFU
TC2
2
---
CH
---
0
---
CH
---
2
EU (See
CH
---
note.)
0
---
CH
---
0
---
CH
---
TC4
---
Defau-
Unit
Attribut-
Target Unit
lt
es
TC4/
HFU
TC2
0
---
IO
TC2
---
0.1
A
IO
TC2
---
0
---
IO
TC2
---
0.1
A
IO
TC2
---