Safety i/o terminals
Table of Contents

Advertisement

Examples of Wiring for Each Application
8-2-2
Two-Hand Input
Wiring
Configuration
Parameter
Group
Safety Input 0
0008
0009
0054
0055
Safety Input 1
0012
0013
Safety Input 2
0016
0017
0056
0057
Safety Input 3
0020
0021
Test Output 0
0001
Test Output 1
0002
92
An example of the wiring and configuration when using the DST1-ID12SL-1 is
shown below.
V
IN0
IN1
G
T0
T1
E1
GND
S11
Parameter Name
Safety Input 0 Channel Mode
Safety Input 0 Test Source
Dual Channel Safety Input 0/1 Mode
Dual Channel Safety Input 0/1 Discrepancy Time
Safety Input 1 Channel Mode
Safety Input 1 Test Source
Safety Input 2 Channel Mode
Safety Input 2 Test Source
Dual Channel Safety Input 2/3 Mode
Dual Channel Safety Input 2/3 Discrepancy Time
Safety Input 3 Channel Mode
Safety Input 3 Test Source
Test Output 0 Mode
Test Output 1 Mode
IN2
IN3
E1: 24-V DC Power Supply (S8@@)
S11,S12: Two-hand control switches
T0
T1
S12
Test pulse from test output
Test Output 0
Dual Channel Complementary
100 x 10 ms
Test pulse from test output
Test Output 0
Test pulse from test output
Test Output 1
Dual Channel Complementary
100 x 10 ms
Test pulse from test output
Test Output 1
Pulse Test Output
Pulse Test Output
Section 8-2