Remote I/O Allocations
Data
Input data
General Status Data
Output data
Safety Output Data
SAFE
Safety Output Data and Output
Condition Signal (DST1-
XD0808SL-1 only)
SAFE
Output Condition Signal (DST1-
XD0808SL-1 only)
Standard Output Data
Input Condition Signal (DST1-
XD0808SL-1 only)
SAFE
Reset Signal (DST1-XD0808SL-1
only)
Note
3-2-3

I/O Data Supported by Each Model

38
DST1-ID12SL-1
DST1-MD16SL-1
DST1-MRD08SL-1
Bit 0 Safety Input Power Status Flag
0: Input power supply ON
1: Input power supply OFF
Bit 1 Safety Output Power Status Flag
0: Output power supply ON
1: Output power supply OFF
Bit 2 Network Power Voltage Drop Flag
0: Normal (higher than set monitor value)
1: Error (same as or lower than set monitor value)
Bit 3 Unit Maintenance Flag
0: Within range (lower than set monitor value)
1: Over range (same as or higher than set monitor value)
Bit 4 Reserved
Bit 5 Combined I/O Port Status Flag
0: Normal (all I/O points normal)
1: Error (one or more I/O point error)
Bit 6 Operation Time Exceeded Flag
0: Within range (all I/O values are
lower than set monitor value)
1: Over range (one or more value is
same as or higher than set value)
Bit 7 Connected Component Maintenance Flag
0: Within range (all I/O points are lower than set monitor value)
1: Over range (one or more I/O point is same as or higher than set monitor
value)
Controls the safety output terminal.
• ON: 1
• OFF: 0
When the safety output terminal is set to Output from network:
Safety output terminal ON/OFF status
• ON: 1
• OFF: 0
When the safety output terminal is set to Output from internal logic:
Remote I/O signal for output condition operation
• ON: 1
• OFF: 0
Remote I/O signal for output condition operation
When the safety output terminal is set to Output from internal logic:
• ON: 1
• OFF: 0
Controls the test output when test output mode is set to a standard output.
• ON: 1
• OFF: 0
Input condition signal for safety inputs. Used for input condition operations.
• ON: 1
• OFF: 0
Reset signal for safety inputs. Used for reset operations.
• ON (High): 1
• OFF (Low): 0
Turns OFF when one of the errors shown in 7-3 Error History occurs.
The following tables show the I/O data supported by each model of the DST1-
series Safety I/O Terminals.
Refer to 3-2-4 I/O Assembly Data for data arrangements.
Description
DST1-XD0808SL-1
Operating Mode Flag
0: Not RUN mode
1: RUN mode
Status Flag
0: Error (See note.)
1: Normal