Test 7 Stitch-Width Stepping Motor Test; Test 8 The Two Stepping Motors In Pinning Position - Bernina 330 Service And Maintenance Manual

Hide thumbs Also See for 330:
Table of Contents

Advertisement

Repair notes:
If «F» (for 'error') appears instead of «ok», the cause might be mechanical stiff-running.
RPM calibration factor can be read in test 11.
Before repeating the test, mechanical smooth-running must be ensured.
Check cables and connectors for deformation and/or wear and tear.
Replace PCBA-Base
Replace PCBA-Power
Do not remove or plug in any connections when the sewing computer is switched on or
connected to the power supply.

Test 7 Stitch-width stepping motor test

Set needle bar to top dead centre (TDC).
Select test no. 7.
Target state:
Stitch-width stepping motor turns back and forth.
Stitch-width bar display flashes.
Needle bar moves back and forth.
Press clr to exit test and to return to service program basic position.
Repair notes:
Swap connections of stepping motors on PCBA-Base to find the defective PCB.
If the stepping motor doesn't move, the fault might be with the stepping motor or the
PCBA-Base.
If the needle bar doesn't move at all or not entirely from left to right, the needle-bar
support must be checked for mechanical smooth-running.
Do not remove or plug in any connections when the sewing computer is switched on or
connected to the power supply.

Test 8 The two stepping motors in pinning position

Set needle bar to top dead centre (TDC).
Select test no. 8.
Target state:
The stepping motors are powered to the stepping
parameter of the pinning position.
«P» appears in the display.
Press clr to exit test and to return to service program basic position.
Note: This test is only used on stepping motors out of the machine.
BERNINA International AG · Seestrasse 161 · CH-8266 Steckborn · Switzerland
(Chapter 2 Item 2.3
PCBA-Base).
(Chapter 4 Item 4.2.4
PCBA-Power).
55