The water cooler object was
not found and is required in the
system.
The Flexstart object was not
found and is required in the
system.
Switch board auxiliary supply
voltage is too high at machine
power-up.
Switch board auxiliary supply
voltage is too low at machine
power-up.
FlexCut® 200 Service Manual
Connect a water cooler that
has a control board (FlexCool
35).
If not using a water cooler,
reset the 'Fault if No Cooler'
attribute using Power Wave
Manager Misc tab.
If using a Water Cooler, verify
the board is properly
connected in the system.
Connect a Flexstart.
Improper input voltage
configuration. Verify primary
reconnect position, measure
input voltage level and check
three phase operation.
Damaged auxiliary transformer
(T2) or intermittent "A" lead
connection.
Replace defective user
interface board.
Improper input voltage
configuration. Verify primary
reconnect position, measure
input voltage level and check
three phase operation.
Damaged auxiliary transformer
(T2) or intermittent "A" lead
connection.
Replace defective user
interface board assembly.