TEST POINT
L1
L2
L3
L1
L2
L3
Table F.10 – Input switch resistance tests
TEST POINT
L1A
L2A
L3A
L1A
L2A
L3A
Figure F.28 – Input switch location
FlexCut® 200 Service Manual
EXPECTED READING
VERY LOW RESISTANCE
(LESS THAN ONE OHM)
VERY LOW RESISTANCE
(LESS THAN ONE OHM)
VERY LOW RESISTANCE
(LESS THAN ONE OHM)
HIGH RESISTANCE
(GREATER THAN 50OK
OHMS)
HIGH RESISTANCE
(GREATER THAN 50OK
OHMS)
HIGH RESISTANCE
(GREATER THAN 50OK
OHMS)
SWITCH POSITION
"ON" POSITION
"ON" POSITION
"ON" POSITION
"OFF" POSITION
"OFF" POSITION
"OFF" POSITION