4. Connect leads 207, 209, L1A, L1B, L2A, L3A and H1 to the input rectifier (D1). See Wiring Diagram.
5. Using a 5/16" nutdriver, attach the five screws, lock washers and flat washers securing the leads to
the input rectifier (D1). See Wiring Diagram.
6. Apply a heavy coating of silicone sealant to protect the lead connection points.
7.
Perform the
Case Cover Replacement
8. Perform the Retest After Repair Procedure.
Figure F.56 – Input rectifier (D1) lead locations
Figure F.57 – Input rectifier (D1) mounting hardware locations