Download Print this page

Advertisement

Quick Links

IM2075
02/2017
REV00
FLEXTEC 350x CE
OPERATOR'S MANUAL
ENGLISH
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA
www.lincolnelectric.eu

Advertisement

loading

Summary of Contents for Lincoln Electric FLEXTEC350x CE CONSTRUCTION

  • Page 1 IM2075 02/2017 REV00 FLEXTEC 350x CE OPERATOR’S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA www.lincolnelectric.eu...
  • Page 2 THE LINCOLN ELECTRIC COMPANY EC DECLARATION OF CONFORMITY Manufacturer and technical The Lincoln Electric Company documentation holder: Address: 22801 St. Clair Ave. Cleveland Ohio 44117-1199 USA EC Company: Lincoln Electric Europe S.L. Address: c/o Balmes, 89 - 8 08008 Barcelona...
  • Page 3: Table Of Contents

    12/05 THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 4: Technical Specifications

    Technical specifications K4283-1 FLEXTEC350x CE CONSTRUCTION K4284-1 FLEXTEC350x CE STANDARD POWER SOURCE – INPUT VOLTAGE AND CURRENT Input Model Duty Cycle Input Voltage ±10% Idle Amperes Power Factor Amperes 60% rating 380/460/575 3PH 24/22/22 .13/.16/.27 .87/.77/.62 K4283-1 K4284-1 100% rating...
  • Page 5 Lincoln Electric. Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances.
  • Page 6: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 7: Installation

    CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do not move or transport gas cylinders with the protection cap removed.
  • Page 8  Variable Hot Start – Get the extra starting Input and Ground Connections amperage you need for thick, rusty or dirty material.  Variable Arc Control – In stick mode, vary the arc The Flextec 350x CE comes standard with a power force to obtain the “soft”...
  • Page 9 Case Front Control Standard Case Front Control Construction Thermal LED: A yellow light that comes on when Thermal LED: A yellow light that comes on when an over temperature situation occurs. Output is an over temperature situation occurs. Output is disabled until the machine cools down.
  • Page 10 Case Back Controls Factory Default Setting All Switches in the ‘OFF’ Position Test Mode Setting Enter a test mode. This is utilized when the machine is connected to a grid load for serving Turn switch #4 to the "ON" position. Switch #4 in the ‘ON’...
  • Page 11 Arclink Wire Feeder & Digital Accessory Connectivity Socket 1: 12-Pin Remote Control Connector Picture Function Wiring ARCLINK CAN ARCLINK CAN REMOTE POTENTIOMETER COMMON 12-PIN REMOTE REMOTE POTENTIOMETER CONTROL WIPER CONNECTOR REMOTE FOR REMOTE POTENTIOMETER +10V HAND/FOOT AMPTROL AND ALPS CONNECTION DIGITAL TRIGGER ACCESSORIES...
  • Page 12 Recommended Electrode and Work Cable Sizes for Arc Welding Connect the electrode and work cables between the appropriate output studs of the Flextec 350x CE per the following guidelines:  Most welding applications run with the electrode being positive (+). For those applications, connect the electrode cable between the wire drive feed plate and the positive (+) output stud on the power source.
  • Page 13 Remote Sense Lead Specifications Genuine Lincoln Electric control cables should be used at all times (except where noted otherwise). Lincoln Electric cables are specifically designed for the communication and power needs of the Flextec 350x CE. Most are designed to be connected end-to- end for ease of extension.
  • Page 14 Connecting LF-72 and LF-74 to the Flextec 350x CE WIRE FEEDER 14PIN CONTROL CABLE K1797-XX ELECTRODE WORK CONTROL SETTING WELD MODE CV, CV-INNERSHIELD WELD TERMINALS REMOTELY CONTROLLED LOCAL REMOTE/LOCAL (REMOTE IF K2329-1 INSTALLED) VOLTMETER POLARITY PROCESS DEPENDENT English English...
  • Page 15 Connecting LN-10 and DH-10 to the Flextec 350x CE WIRE FEEDER 14 PIN CONTROL CABLE K1501-XX ELECTRODE WORK CONTROL SETTING WELD MODE CV, CV-INNERSHIELD WELD TERMINALS REMOTELY CONTROLLED REMOTE/LOCAL REMOTE VOLTMETER POLARITY PROCESS DEPENDENT Setting the DIP Switches LN-10,DH-10 Control Switch Setup The DIP switches are each labeled with an “ON”...
  • Page 16 Connecting Active 8, LN-25 Pro Series, LN-25 Pipe, LN-25 Ironworker and LN-25x to the Flextec 350x CE WIRE FEEDER ELECTRODE WORK CLIP WORK CONTROL SETTING WELD MODE CV, CV-INNERSHIELD WELD TERMINALS REMOTE/LOCAL LOCAL OR REMOTE WHEN USING CROSSLINC VOLTMETER POLARITY PROCESS DEPENDENT Connecting LN-25 Pro Dual Power to the Flextec 350x CE WIRE FEEDER...
  • Page 17 Connecting Arclink Feeder to the Flextec 350x CE WIRE FEEDER ARCLINK CABLE K1543-XX ARCLINK FEEDERS ELECTRODE WORK CONTROL SETTING WELD MODE ARCLINK WELD TERMINALS REMOTE N.A. REMOTE/LOCAL N.A. VOLTMETER POLARITY N.A. English English...
  • Page 18: Operation

    Operation Power-up Sequence GTAW – This is a CC (constant current) weld mode used for the GTAW tig welding process. When power is applied to the Flextec 350x CE, the SMAW – This is a CC (constant current) weld mode displays will illuminate and the machine electronics will used for the SMAW stick welding process.
  • Page 19 Hot Start Dial Amperage Display Meter The Hot Start control regulates the starting current at arc initiation. Hot Start can be set to ‘0” and no additional current is added at arc start. Increasing from 0 to 10 will increase the additional current (relative to the preset current) that is added at arc initiation.
  • Page 20 Thermal Light VRD Lights There are two indicator lights on the case front of the This status light indicates when the power source has Flextec 350x CE above the Voltage display to indicate been driven into thermal overload. If the output terminals the status of VRD operation.
  • Page 21  When a remote potentiometer is connected, the output control on the Flextec and the remote act as a master/slave config- uration. Use the output control dial on the Flextec to set the maximum welding current. The remote will control output from minimum to the pre-set maximum.
  • Page 22 to adjust the voltage with a master/slave source such as the Flextec350x CE and a CrossLinc relationship with the output control dial. enabled wire feeder such as the LN25x, welding  When set to the ‘remote’ position, output is enabled voltage can be controlled remotely without the use of an additional control cable.
  • Page 23 Voltage Display – This display will display the pre-set welding voltage when the machine is in the idle state. Maintenance After welding, the meter holds the actual voltage value WARNING for 5 seconds. Output adjustment while in the "hold" Before carrying out service, maintenance period results in the "prior to operation"...
  • Page 24 Lincoln Electric is not in a position to warrant or Put dipswitch 1 in the on postion. guarantee such advice, and assumes no liability, with Rotate the Hot Start knob and Arc Control knob to respect to such information or advice.
  • Page 25: Weee

    WEEE 07/06 Do not dispose of electrical equipment together with normal waste! In observance of European Directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility.
  • Page 26: Electrical Schematic

    Electrical Schematic WIRING DIAGRAM – CODE 12679 (FT350x Standard K4284-1) NOTE: this diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a partiuclar code is pasted inside the machine on one of the enclosure panels. If the diagram is ellegible, write to the Service Department for a raplacement.
  • Page 27 WIRING DIAGRAM – CODE 12678 (FT350x Construction K4283-1) NOTE: this diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a partiuclar code is pasted inside the machine on one of the enclosure panels. If the diagram is ellegible, write to the Service Department for a raplacement.
  • Page 28: Suggested Accessories

    DC welding power source and the work clamp. Weld Fume Control Solutions. Lincoln Electric offers a wide variety of welding fume control solutions, ranging from portable systems easily wheeled around the shop to shop-wide central systems servicing many dedicated...
  • Page 29 GRD-400A-70-xM* Ground cable 400A 70 mm²; x=5/10/15 m E/H-400A-70-xM* Electrode holder 400A/70mm²; x=5/10m KIT-400A-70-5M Cable kit 400A, 70mm2, 5m Tig Options K870-2 Foot Amptrol®. Provides 25 ft. (7.6 m) of remote current control for TIG welding. (12-pin plug connection). K963-4 Hand Amptrol®...

This manual is also suitable for:

Flextec350x ce standardK4283-1K4284-1