Table F.8 – Switch board LED functions
LIGHT CONDITION
MEANING
STEADY GREEN
SYSTEM OK.
BLINKING GREEN
OCCURS DURING STARTUP OR RESET AND INDICATES THAT THE SWITCH BOARD
STATUS IS WAITING FOR COMMUICATION FROM THE USER INTERFACE BOARD.
NORMAL FOR THE FIRST 1-10 SECONDS AFTER POWER IS TURNED ON.
ALTERNATING GREEN
A SYSTEM FAULT HAS OCCURRED. IF THE SWITCH BOARD STATUS LED IS FLASHING
AND RED
ANY COMBINATION OF RED AND GREEN, ERRORS ARE PRESENT.
INDIVIDUAL CODE DIGITS ARE FLASHED IN RED WITH A LONG PAUSE BETWEEN
DIGITS. IF MORE THAN ONE CODE IS PRESENT, THE CODES WILL BE SEPARATED BY
A GREEN LIGHT. SEE ERROR CODES IN TROUBLESHOOTING GUIDE.