IBM 3270 Manual page 255

Using the control program
Hide thumbs Also See for 3270:
Table of Contents

Advertisement

INDSY
If you are not sure whether the drive is defective,
go to the chapter that deals with problems in
your Guide to Operations.
INDSY050
DOS error for PC session in
window x
Abort, Fail, or Retry
Explanation: This message can appear with
messages INDSY053 through INDSY060. The
variable information is the personal computer
window short name where the DOS error
appears. Respond to the associated message first.
User Response:
Type A to terminate the application through
an INT '23'X.
Type F to fail the DOS function call that
caused the error. The program may continue
runnIng.
Type R to try the application again.
INDSY051
DOS error for control program
Abort, Fail, or Retry
Explanation: This message can appear with
messages INDSY053 through INDSY060. The
control program issued a DOS function call that
encountered an error. Respond to the associated
message first.
User Response:
Type A to terminate the application through
an INT '23'X.
Type F to fail the DOS function call that
caused the error. The program may continue
runnIng.
Type R to try the application again.
A-70