C. FIELD WIRING COMPARTMENT – 230 V, 50
HZ, -JB MODELS
WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to the
Important Information located on Page 2.
CAUTION: Risk of electrical shock. All services
must have an Earth-Leakage Circuit-Breaker
(ELCB) which will provide additional protection
against line-to-ground shock hazard.
The bath controls and system have been prewired at the
factory. A licensed electrician should make a routine
service connection to the field wiring compartment of the
junction box containing blue and brown wires and earth
lug.
* For bonding in accordance with national and local
codes.
D. CONNECT WIRING IN JUNCTION BOX – 230
V, 50 HZ MODELS
Connect service to the field wiring compartment of the
junction box. The 50 Hz model junction box contains blue
and brown wires and earth lug.
A 230 V, 10 A, 50 Hz dedicated circuit is required.
Provide an Earth-Leakage Circuit-Breaker.
Provide a separate equipment earthing conductor for the
inside earth lug. The earthing conductor must not be
connected to any current carrying conductor. Follow
local electrical codes.
9. WATER TEST WHIRLPOOL AND ELECTRONICS
Check all electrical connections.
Make sure the pipe connections to the pump are
securely tightened.
Fill the whirlpool to a level at least 2" (5.1cm) above the
top of the highest jet.
Operate the whirlpool for 5 minutes, and check all
whirlpool harness (piping) connections for leaks.
Turn on the neck jet feature, and check for any water
leakage on the whirlpool's back side.
For additional information on whirlpool operation, see
Start-Up Whirlpool instructions on Page 14.
BB
114047-2-
Pump
Switch
Auxiliary
Control
Bonding
(Earthing) Lugs*
Earth
(Ground)
Neutral
(Blue)
Electrician to
provide suitable
strain relief
Neutral
12
Neck Jet
Switch
Junction Box
To Neck
Jets
Pump
Control Box
Wire Connectors
From Pump
Phase
(Brown)
Phase