1. ROUGHING-IN: K-1312-N, K-1312-JB

A. ORDERING INFORMATION
Accessories/hardware:
Jet trim kit
K-9698
Drain
K-7161-AF
Apron
K-1311
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI) (60 Hz) or
Earth-Leakage Circuit-Breaker (ELCB) (50 Hz):
Pump/control/heater
120 V, 20 A, 60 Hz
6-1/8"
21"
25-3/8"
3-1/2"
1.25>132
BB
114047-2-
required
recommended
optional
11-1/8"
68"
3"
21"
2-7/8"
3/8"
1-1/2" I.P.S. THR'D.
3"
C. PRODUCT INFORMATION
Fixture:
basin area
Bathing well 47" x 26"
water depth
To overflow
15-1/2"
Pump, 1-speed:
60 Hz
50 Hz
D. INSTALLATION NOTES
Read the entire installation instruction before beginning the
installation.
The K-1311 apron, if used, must be installed BEFORE fin-
ished flooring is laid.
If installing a rim-mount faucet, make sure there is no
interference with drain overflow and circulating system
before drilling any holes. Consult local and national codes
for minimum air gap requirements if installing a spout on
the faucet deck.
ROUGHING-IN NOTES
Fixture conforms to ANSI Standard Z124.1. All
dimensions are nominal.
No change in measurements if connected with drain
illustrated.
Minimum access:
Pump/control
PUMP/CONTROL ACCESS
42"
1-1/4"
1-1/2" O.D.
4
top area
weight
64" x 31"
140 lbs.
capacity
91 gals.
HP
V
Hz
2
120
60
2
230
50
40" W x 15" H panel required
66"
33"
16"
49" R.
CUT-OUT DETAIL
Kohler Co., Kohler, WI U.S.A.
A
18.5
9.5
18"
20"
2"