9. FIELD WIRE COMPRESSOR

A. SERVICE REQUIREMENTS
The compressor has been prewired at the factory. A
licensed electrician should make a routine service
connection to the field wiring compartment of the
compressor control containing black and white wires
and ground lug.
See Electrical Requirements section on page 5 of
Product Requirements.
WARNING: Risk of electrical shock. A licensed
electrician should make all electrical connections.
WARNING: Risk
Disconnect and lock out power before performing
the following procedures. Refer to Important
Safety Instructions on page 2.
B. IDENTIFY ELECTRICAL REQUIREMENTS
The model number is printed on a plate at the seat end
of the module.
The model number identifies electrical rating. Electrical
connections for each model vary.
S K-1353-AA, K-1354-AA:
C. CONNECT CONTROL - 120 V, 60 HZ
Connect service to the field wiring compartment of the
control box. The 60 Hz model compressor control
contains black and white wires and ground lug.
A 120 V, 15A dedicated circuit is required. Provide a
Class A Ground-Fault Circuit-Interrupter.
Provide a separate equipment grounding conductor for
the inside grounding lug.
connected to any current-carrying conductor except at
the main service breaker box (per National Electrical
Code, Article 250-61-b).
Kohler Co., Kohler WI
of
electrical
shock.
60 Hz
Ground must not be
Wire
White Wires
Nut
Black
(Neutral)
Wire
(Line)
Bonding
Lug
Green
Ground
Wire
Lug
(Ground)
11
Water Level
Sensor
CA
113019-
(1093)