Field Wire Electronics; Identify Electrical Requirements; Wiring Information - 120 V, 60 Hz; Field Wiring Control Box Compartment - 230 V, 50 Hz - Kohler Maestro K-842-V-AB Installation Instructions Manual

Whirlpool baths
Table of Contents

Advertisement

9. FIELD WIRE ELECTRONICS

A. IDENTIFY ELECTRICAL REQUIREMENTS
The model number is printed on a plate at the pump end
of the module.
The model number identifies electrical rating. Electrical
connections for each model vary.
S K-842-V-AB, K-845-V-AB:
(Follow Step B. below.)
S K-842-JA-AA, K-845-JA-AA:
(Follow Steps C. and D. below.)
See Electrical Requirements section on page 6 of
Product Requirements.
B. WIRING INFORMATION - 120 V, 60 HZ
(EXCLUDING -J1 MODELS)
WARNING: Risk of electrical shock. To reduce
the risk of electric shock, connect only to a properly
grounded, grounding-type receptacle, protected
by a Ground-Fault Circuit-Interrupter (GFCI). Do
not remove the plug's grounding pin. Do not use a
grounding adapter.
Your Kohler Whirlpool bath is equipped with a cord and
plug. All wiring of the pump and control has been
completed at the factory. A licensed electrician must
install a GFCI protected, 120 Volt, 15 Amp, grounded
outlet. Your whirlpool may then be plugged into this
outlet. No other load should be on this circuit. Locate the
outlet within reach of the 36" cord.
C. FIELD WIRING CONTROL BOX
COMPARTMENT - 230 V, 50 HZ
WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to
Important Safety Instructions located on page 2.
CAUTION: Risk of electrical shock. All services
must have an Earth Leakage Circuit Breaker
(ELCB) which will provide additional protection
against line-to-ground shock hazard. A separate
service is required for the whirlpool.
The whirlpool controls and system have been prewired
at the factory. A licensed electrician should make a
routine
service
connection
compartment of the control box containing blue and
brown wires and earth lug.
* For bonding in accordance with National and Local
Codes.
Kohler Co., Kohler WI
60 Hz
50 Hz
to
the
field
wiring
Pump
11
Air
Actuator
Control
Box
Air
Actuator
Tube
Field Wiring
Compartment
Bonding
(Earthing) Lug*
CA
111835-
(1093)

Advertisement

Table of Contents
loading

Table of Contents