Code
[9.2.1]
[E‑05]
[E‑06]
[E‑07]
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
• [E-05]: Can the system prepare domestic hot water?
• [E-06]: Is a domestic hot water tank installed in the system?
• [E-07]: What kind of domestic hot water tank is installed?
In case of EKHWP, we recommend to use the following settings:
#
Code
[9.2.1]
[E‑07]
Tank type
N/A
[4-05]
Thermistor type
[5.8]
[6-0E]
Maximum tank
temperature
In case of EKHWS*D* / EKHWSU*D*, we recommend to use the following settings:
#
Code
[9.2.1]
[E‑07]
Tank type
N/A
[4-05]
Thermistor type
[5.8]
[6-0E]
Maximum tank
temperature
In case of a third-party tank, we recommend to use the following settings:
#
Code
[9.2.1]
[E‑07]
Tank type
N/A
[4-05]
Thermistor type
(a)
No DHW
(a)
No tank installed.
(a)
EKHWS/E, small volume
Tank with booster heater installed at the side of
the tank, with a volume of 150 l or 180 l.
EKHWS/E, big volume
Tank with booster heater installed at the side of
the tank, with a volume of 200 l, 250 l or 300 l.
EKHWP/HYC
Tank with optional booster heater installed at
the top of the tank.
3rd party, small coil
Third-party tank with a coil size larger than
1.05 m².
3rd party, big coil
Third-party tank with a coil size larger than
1.80 m².
Item
Item
0: EKHWS/E,
small volume
0: Automatic
Item
Coil≥1.05 m²
7: 3rd party,
small coil
0: Automatic
Description
EKHWP
5: EKHWP/HYC
0: Automatic
≤80°C
EKHWS*D* / EKHWSU*D*
150/180
200/250/300
3: EKHWS/E, big
volume
1: Type 1
≤60°C
≤75°C
Third-party tank
Coil≥1.8 m²
8: 3rd party,
big coil
1: Type 1