10
|
Configuration
Electricity prices and gas price
About energy prices in case of an incentive per kWh renewable energy
Installer reference guide
196
3 Define the restrictions (time + level) to be used after midday
(PM):
[7.4.4.4] PM Restricted time
Example: From 3 p.m. to 7 p.m.
[7.4.4.5] PM Restricted level
Example: Most quiet
Possible outcomes when quiet mode is set to Automatic
If...
Restrictions
Restrictions
enabled?
(time + level)
defined?
No
N/A
Yes
Yes
Only applicable in combination with the bivalent function. See also
4
"Bivalent" [
 219].
#
Code
[7.5.1]
N/A
[7.5.2]
N/A
[7.5.3]
N/A
[7.6]
N/A
INFORMATION
Electricity price can only be set when bivalent is ON ([9.C.1] or [C-02]). These values
can only be set in menu structure [7.5.1], [7.5.2] and [7.5.3]. Do NOT use overview
settings.
An incentive can be taken into account when setting the energy prices. Although
the running cost can increase, the total operation cost, taking into account the
reimbursement will be optimized.
NOTICE
Make sure to modify the setting of the energy prices at the end of the incentive
period.
Schedule
programmed?
No
Yes
No
No
Yes
No
Yes
Electricity price > High
Electricity price > Medium
Electricity price > Low
Gas price
Then quiet mode =...
OFF
Follows schedule
OFF
Follows schedule
Follows restriction
During restricted time: If
restricted level is stricter than
scheduled level, then follows
restriction.
Else,
schedule.
Outside
restricted
Follows schedule.
Description
EPRA14~18D + ETBH/X16E
Daikin Altherma 3 H HT W
4P644736-1D – 2023.10
follows
time:

Advertisement

Table of Contents
loading

Table of Contents