Daikin ETBH16E9W Installer's Reference Manual page 195

Table of Contents

Advertisement

EPRA14~18D + ETBH/X16E
Daikin Altherma 3 H HT W
4P644736-1D – 2023.10
To check if quiet mode is active
If
is displayed on the home screen, quiet mode is active.
To use quiet mode
1 Go to [7.4.1]: User settings > Quiet > Mode.
2 Do one of the following:
If you want to...
Completely deactivate quiet
mode
Manually activate a quiet
mode level
Enable the user to program a
quiet mode schedule, AND/
OR
Configure restrictions based
on local regulations
To configure restrictions
1 Enable the restrictions.
Go to [7.4.4.1]: User settings > Quiet > Restrictions >
Enable and select Yes.
2 Define the restrictions (time + level) to be used before midday
(AM):
[7.4.4.2] AM Restricted time
Example: From 9 a.m. to 11 a.m.
[7.4.4.3] AM Restricted level
Example: More quiet
Then...
Select Off.
Result: The unit never runs in quiet
mode. The user cannot change this.
Select Manual.
Go to [7.4.3] Level and select the
applicable quiet mode level.
Example: Most quiet.
Result: The unit always runs in the
selected quiet mode level. The user
cannot change this.
Select Automatic.
Result:
The user (or you) can program the
schedule in [7.4.2] Schedule. For
more
information
scheduling, see
"10.3.7  Schedule
4
screen:
Example" [
 147].
You can configure restrictions in
[7.4.4]
Restrictions.
below.
The possible outcomes for the
quiet mode differ depending on
the schedule (if programmed) and
the
restrictions
(if
defined). See below.
10
Configuration
|
about
See
enabled/
Installer reference guide
195