To prepare stranded conductor wire for installation
Method 1: Twisting conductor
1 Strip insulation (20 mm) from the wires.
2 Slightly twist the end of the conductor to create a "solid-like" connection.
Method 2: Using round crimp-style terminal
1 Strip insulation from wires and slightly twist the end of each wire.
2 Install a round crimp-style terminal on the end of the wire. Place the round
crimp-style terminal on the wire up to the covered part and fasten the
terminal with the appropriate tool.
Use the following methods for installing wires:
Wire type
Single-core wire
Or
Stranded conductor wire
twisted to "solid-like"
connection
Installation method
c b
A
c
a
a Curled wire (single-core or twisted stranded
conductor wire)
b Screw
c Flat washer
9
Electrical installation
|
AA´
a
Installer reference guide