MASTER SETTINGS REFERENCE CHART

Before entering Master Settings, please contact your local professional water dealer.
CAUTION
Screen Name
Parameters
Format
Language
Units
Hardness Units
Assistance Name
Free-form text
Assistance Phone
Free-form text
Assistance Interval
Month Based
Regen Based
Valve
System
Valve
Media Volume
Salt Dosage
BLFC size
Regen. Type
Capacity
Hardness
Reserve
Day Override
Regen Time
Volume Override
Regeneration
Regen. Flow
Relay Outputs
Aux 1/Aux 2
Meter
Meter Type
Generic
Remote Regen
Remote Regen
NOTE: Some items may not be shown depending on control configuration. The control will discard any changes and exit Master Settings if any button is not pressed for five minutes.
18 • FLECK 5800 XTR2 Service Manual
Values
English, French,
Changes the language to display screen text and button labels in the control (available with international
German, Italian,
version of control only).
Spanish, Dutch
U.S.
Changes system units and values across all parameters in the control. All programmed units and values
Metric
should be recalculated after adjusting this setting.
Grains per gallon
Changes hardness units used in displaying hardness parameters and calculating system capacity and editing
mg/L or ppm
exchange capacity and hardness settings. The hardness units setting is not available when regen. type; tank
German degrees
sensor has been selected.
French degrees
English degrees
A - Z and space
Name of service provider to display when viewing the Assistance screen. 20 character limit.
0 - 9 and space
Phone number of service provider to display when viewing the Assistance screen. 20 character limit.
1 - 60
Set to automatically display the Assistance screen after a certain number of months or regenerations.
1 - 2000
Off
4
System 4 (single system) is currently the only available selection.
5800
Select the type of valve to be installed.
5810
5812
0.25 - 999.00 ft
Used to calculate capacity.
1 - 9999 L
3 - 18 lbs/ft
Used to calculate capacity and refill time.
50 - 290 g/L
0.125 gpm
Brine Line Flow Control; Used to calculate refill time.
0.250 gpm
0.500 gpm
1.000 gpm
Time Clock
Regeneration Types are described in detail on page 13.
Softener Immediate
Additional Valve screen parameters are dependent upon selected Regeneration Type. Not all parameters will
Softener Delayed
be displayed.
Sensor Softener Delayed
Softener Delayed regeneration type has four reserve options (Fixed %, Fixed Volume, Variable Reserve, Weekly
Filter Immediate
Reserve). The control will display additional configuration options depending on the selected reserve type.
Filter Delayed
1 - 99 999 999
Only required on metered systems to calculate treated water capacity and reserve. Represents total system
grains / grams / degrees
capacity between regenerations.
1 - 199 grains/gallon
Only required on metered systems to calculate treated water capacity and reserve. Represents hardness of
1 - 1 999 mg/liter
untreated water. The hardness units setting is not available when regen. type; tank sensor has been selected.
x - x degrees
Fixed %
Only available when Meter Delayed regeneration type is selected.
Fixed Volume
Selecting Fixed % or Fixed Volume will display additional configuration options.
Weekly Reserve
Weekly Reserve is calculated based on average day of week's water usage.
Variable Reserve
Variable Reserve is calculated based on previous day's water usage.
1 - 99 days
Available to be programmed for all Regeneration Types.
4, 8, 12, 16, 20 hours
12 / 24 hour clock
Required for Time Clock and delayed Regeneration Types. Set for immediate regeneration types only when a
Day Override is also set.
1 - 99 999 999 gallons / liters
Only displayed when Regeneration Type is Filter Immediate or Filter Delayed.
Upflow
Cycle steps on the Home screen and during regeneration will change to reflect the cycle steps and order in
Downflow
the selected Regenerant Flow.
Downflow 2x Backwash
Additional Regeneration screen parameters are dependent upon selected Regenerant Flow. Not all
Filter
parameters will be displayed.
Custom Upflow/Downflow/Filter
Custom Upflow and Downflow allows for up to 20 programmable cycle steps.
Variable Refill
Variable Refill calculates refill time based on Salt Dosage, Media Volume, and BLFC Size.
Time per cycle step can be programmed for all other Regenerant Flow options.
Cycle Based
For Cycle Based relays, select the cycle steps on which the relays will turn on. For Time Based relays, two
Time Based
start/end times will need to be selected for each relay. Relay times are based on total regeneration cycle time.
Volume Based
Volume Based relays can be programmed from zero gallons/liters to the full system capacity. Duration can be
Alarm Based
set from zero seconds to two hours. Volume Based option is not available when Regeneration Type is set to
Off
Time Clock. Alarm Based relays will turn on when an alarm condition is met, and will turn off when the alarm
is cleared.
.75 inch Paddle
Select the type of meter installed with the system. A Generic option is available if the installed meter does not
1.00 inch Paddle
match any other selection. Selecting the Generic meter type requires setting the number of pulses per gallon
1.25 inch Turbine
or liter to ensure proper metering.
1.50 inch Paddle
1.50 inch Turbine
2.00 inch Paddle
3.00 inch Paddle
Generic
1 - 999.9 /1 - 1500
Only available when Generic meter type is selected.
pulses per gallon / liter
1 - 255 seconds
Select a value in seconds that the remote switch must be closed in order to trigger the regeneration.
Off
Notes
262.634.2386 | greatlakesintl.com