pH Settings and ORP Settings Buttons

pH Dosage (dispense acid)
system. Combining these two chemicals without sufficient water flow for mixing
will result in the formation of hazardous gas. This menu item will be displayed as
Override [Wait] during no-flow and flow-delay time period.
pH Settings button: Press the pH Settings
pH
button to access the pH dosage settings.
SETTINGS
ORP Settings button: Press the ORP Settings button
ORP
SETTINGS
to access the Oxidation Reduction Potential (ORP)
settings. The ORP is the sanitization quality of the
water of a given solution.
Note: To exit pH Settings and ORP Settings, press the MENU button.
Password Protect: The pH Settings and ORP Settings screens are not accessible
when the Password Lock is set to "ALL". Set the Password Lock to "OFF" or "MENU" to
access these screens (see page 5).
Override (pH): Press the / Right or Left arrow button to toggle between "Dose"
or "Stop". Select "Dose" to dispense muriatic acid or CO2 and select "Stop" to stop
dispensing acid or CO2 (pH Settings LED is on). To exit, press the MENU button or
press the  Down button to select the "Level Gauge" feature. The Override feature is
not available when CO2 is setup to "Feed to Setpoint."
Override (ORP): Press the / Right or Left arrow button to toggle between "Dose"
or "Stop". Select "Dose" to dispense chlorine (or bromine) and select "Stop" to stop
dispensing chlorine (ORP Settings LED is on). To exit, press the MENU button or press
the  Down button to select the "Level Gauge" feature. The Override feature is not
available when IntelliChlor is setup to "Feed to Setpoint."
Level Gauge indicator: Press the / Up/Down button to select this feature. The
level gauge (volume based) and hour glass (time based) icon is a visual representation
of the amount of acid (pH Settings) or chlorine (ORP Settings) available in the
container. Press / six times to fill the gauge (container full). The indicator displays
six horizontal bars when full. The level gauge is not available if the doser is unable
to determine the pump dispense rate, the supply volume, or if there is no supply
"reminder" set up (see page 13-15). The gauge is displayed as an "hour glass" if the
supply is based on time rather then volume (see page 6)
Limit [Clear]: Press the / to select this feature. Press the / to clear the current
dosage limit timer. After pressing the button, "CLEARED" is displayed, indicating that
the current dosage limit is cleared.
DO NOT manually feed pH (acid) and ORP sanitizer (chlorine)
at the same time without sufficient water flow through the piping
INTELLICHEM
Controller Installation and User's Guide
®
pH Settings
Override [Dose]
Level Gauge:
Limit cleared
ORP Settings
Override [Dose]
Level Gauge:
Limit: [Clear
3
5
5
]