Entering Master Programming Mode:
1.
Press and hold the Shift and Up buttons for 5 seconds.
Press the Extra Cycle button once per display until all displays are viewed and Normal Display is resumed.Option setting
displays may be changed as required by pressing either the Up or Down button. Use the Shift button to move one space
to the left.
2.
Depending on current valve programming, certain displays may not be viewed or set.
NOTE: If the "D" button is pressed while in master programming, no changes will be saved.
NOTE: This screen will not display for
System Type 4.
NOTE: This screen will not display for
System Type 4.
CAUTION: Before entering Master Programming, please contact your local professional water dealer.

Master Programming Mode Flow Chart

Example:
SYSTEM TYPE:
4
System Type 4, Single Unit
SINGLE UNIT
Options: System 4 (single unit)
System 5 (2-4 units)
System 6 (2-4 units)
System 7 (2 units)
System 9 (2-4 units)
Example:
VALVE ADDRESS:
Valve Address #2 (Second Control Valve) (Default)
#2
Options: Valve Address #1 (First Control Valve)
Valve Address #2 (Second Control Valve) (Default)
Valve Address #3 (Third Control Valve)
Valve Address #4 (Fourth Control Valve)
Example:
SYSTEM SIZE:
2 Valves in the System (Default)
2 VALVES
Options: 2 Valves in the System (Default)
3 Valves in the System
4 Valves in the System
Range: 2 to 4 Valves in the System
Example:
REGEN TRIGGER:
Time Clock Delayed (Default)
TIME CLK DELAYED
Options: Time Clock Delayed (System 4 Only) (Default)
Meter Immediate (All System Types)
Meter Delayed Fixed Reserve (Systems 4 & 6 Only)
Remote Signal Start Immediate (All System Types)
Example:
VALVE TYPE:
2750 (Default)
2750
Options: 2750 (Default)
2850
2900
3150
3900
Stager - Butterfly
Stager - Notch Cam
Example:
REGENERANT FLOW:
Downflow (Default)
DOWNFLOW
Options: Downflow (Default)
UF Brine Draw
UF Fill First
Example:
REMOTE SIGNAL
06:00:00 (Default)
START:
00:06:00
(Hours:Minutes:Seconds)
Options: 00:06:00 (Default)