TOUCHSCREEN CONTROL FEATURES
continued
Remote Regeneration Screen
From the secondary Master Settings screen (Figure 19) press
the remote regen button to display the Remote Regen screen.
Figure 21 Remote Regeneration Screen
• remote regeneration duration: Contains settings for
triggering a regeneration via a remote input. Select a
value in seconds that the remote switch must be closed in
order to trigger the regeneration.
Connect a remote switch (such as a differential pressure
switch) to the remote start input terminals on the back of
the XTR2 control board. When the remote switch remains
closed for the number of seconds specified in the Remote
Regen screen, a regeneration will be triggered regardless of
volume, capacity, or time remaining until the next scheduled
regeneration.
Chlorine Generation/Low Salt
(international version only)
From the secondary Master Settings screen (Figure 19) press
the cl generation/low salt button to display the Chlorine Gen/
Low Salt screen (Figure 22).
Figure 22 Chlorine Gen/Low Salt Screen
• cl generation/low salt: Contains settings to trigger
chlorine generator for the control (on/off)
• regen interval range: 1 to 255 regenerations
12 • FLECK 5800 XTR2 Service Manual

MASTER SETTINGS PROGRAMMING

Improperly adjusting master settings may cause
CAUTION
the system to operate incorrectly. Before entering
master settings please contact your professional
water dealer.
NOTE: If a regeneration is scheduled to occur while in
Master Settings, the scheduled regeneration will be
cancelled.
The following is a detailed overview of settings available
in Master Settings. Please see the MASTER SETTINGS
REFERENCE CHART for the complete set of values and ranges
available to program while in Master Settings.
Format Screen
From the main Master Settings screen (Figure 18) press the
format button to display the Format screen.
Figure 23 Format Screen
• language: Displays the language used on the control
(international version only): English, French, German,
Italian, Spanish, or Dutch.
• units: Contains settings for the unit type (either US or
Metric) to be used in the control.
• hardness units: Contains settings for hardness units
of measure (grains per gallon, mg/L or ppm), German
degrees, French degrees, or English degrees). Hardness
units are adjustable only if metric units are selected.
NOTE: The hardness units setting is not available when
regen. type; tank sensor has been selected
NOTE: Degree hardness units are converted to ppm upon
input. Degree inputs may be rounded up or down to
the nearest ppm equivalent.
• Press the screen navigation arrows at the upper-right
and left of the screen to navigate to the Assistance Name,
Assistance Phone, and Assistance Interval screens.
See TOUCHSCREEN CONTROL QUICK START for more
information about these settings.
to save changes.