Pentair FLECK 5800 XTR2 Service Manual

Pentair FLECK 5800 XTR2 Service Manual

Hide thumbs Also See for FLECK 5800 XTR2:

Advertisement

FLECK 5800 XTR2
SERVICE MANUAL
waterpurification.pentair.com

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FLECK 5800 XTR2

  • Page 1 FLECK 5800 XTR2 SERVICE MANUAL waterpurification.pentair.com...
  • Page 2: Table Of Contents

    WARNING: State of California to cause cancer or birth • Correct and constant voltage must be supplied to defects or other reproductive harm. the controller to maintain proper function. 2 • FLECK 5800 XTR2 Service Manual...
  • Page 3: Installation

    When power is control. restored, the time setting must then be re-entered. NOTE: The tank should have the distributor tube installed and have the proper amount of regenerant in place. FLECK 5800 XTR2 Service Manual • 3...
  • Page 4 Faucet Hot Water Grounding Soft Water Outlet Strap Hard Water Bypass Drain Line Water Heater Brine Tank Over ow Drain (Optional) Laundry Tubs Pump Meter Softener Floor Drain Figure 2 Softened Water Flow 4 • FLECK 5800 XTR2 Service Manual...
  • Page 5 The salt tank should have water in it to permit the chlorine solution to be carried into the softener. B. Proceed with the normal recharge. FLECK 5800 XTR2 Service Manual • 5...
  • Page 6: Touchscreen Control Quick Start

    (depending on your previous selection), and select the number of months (up to 60) or regenerations (up to 2000) until the homeowner will need to call for service. Press when finished. Figure 4 Assistance/Mainten. Name Screen 6 • FLECK 5800 XTR2 Service Manual...
  • Page 7 HR changes the display to a 24 hour clock. Press the Day, Month, and Year buttons to adjust the values to the correct date. Press the button when finished to return to the Home screen. Press to return to the Home screen without saving. FLECK 5800 XTR2 Service Manual • 7...
  • Page 8: Touchscreen Control Features

    • Halts all scheduled regenerations when pressed; press • Press to cancel configuration and exit to previous screen again to resume normal operation. When Vacation Mode without saving. is on, the 100 day regeneration error will be suspended. 8 • FLECK 5800 XTR2 Service Manual...
  • Page 9 24 hour clock. Press the Day, Month, and Year buttons to adjust the values to the correct date. Press the button when finished to return to the Home screen. FLECK 5800 XTR2 Service Manual • 9...
  • Page 10 Figure 15 Master Settings Warning Screen the screen will return to the main screen and all • Press to continue to the Password screen or press parameters will be voided. to return to the Home screen. 10 • FLECK 5800 XTR2 Service Manual...
  • Page 11 Types, emergency regeneration. minutes). • settings review: Displays a summary of all programmed • range: 1-25 regenerations (for example, a setting of 3 settings. will produce 1 normal regeneration then 3 reduced water saving regenerations). FLECK 5800 XTR2 Service Manual • 11...
  • Page 12: Master Settings Programming

    • Press to save changes. Figure 21 Chlorine Gen/Low Salt Screen • cl generation/low salt: Contains settings to trigger chlorine generator for the control (on/off) • regen interval range: 1 to 255 regenerations 12 • FLECK 5800 XTR2 Service Manual...
  • Page 13 Measures water usage and regenerates the system at the selected Regeneration Time after the calculated system capacity is depleted. The control calculates the system capacity by dividing the unit capacity by the feed water hardness and subtracting the reserve. FLECK 5800 XTR2 Service Manual • 13...
  • Page 14 0.5 GPM or 1 LPM is detected by alarm condition (or any alarm condition) is met. The the flow meter over an 8-hour period. relay will turn off when the alarm is cleared. 14 • FLECK 5800 XTR2 Service Manual...
  • Page 15 By performing a custom reset, any setting that is subsequently programmed without saving to non-factory settings will be reset to the previously saved non- factory settings in the control. FLECK 5800 XTR2 Service Manual • 15...
  • Page 16 NOTE: Do not remove USB cable from computer or control number is reached, the Totalizer must be reset to zero while connected and transferring data. See the XTR2 to continue tracking this value. Field Programmer manual for proper disconnection procedure. 16 • FLECK 5800 XTR2 Service Manual...
  • Page 17: Master Reset

    See TROUBLESHOOTING for more information about error regeneration cycle from the point where power failed. If power conditions. remains off for more than eight hours, upon power restoration the regeneration is canceled and the piston returns to service. FLECK 5800 XTR2 Service Manual • 17...
  • Page 18: Master Settings Reference Chart

    Select a value in seconds that the remote switch must be closed in order to trigger the regeneration. NOTE: Some items may not be shown depending on control configuration. The control will discard any changes and exit Master Settings if any button is not pressed for five minutes. 18 • FLECK 5800 XTR2 Service Manual...
  • Page 19: Troubleshooting

    (e.g., volume plus reserve) has enabled, the Emegency Regen Occured error alert will display to let the user know been depleted an Emergency Regen occured. Repeated Emergency Regens may indicate an undersized system. FLECK 5800 XTR2 Service Manual • 19...
  • Page 20: Powerhead Assembly

    International Lang 5....1 ..61835 ....Motor Assembly 6....1 ..61882 ....Cover Assy, Environmental, 5800 7....1 ..44161 ....Transformer, 12V UL 8....1 ..44162 ....Transformer, Intl, 12V UL 9....1 ..43715 ....Cover, Lower, Black, 5800 20 • FLECK 5800 XTR2 Service Manual...
  • Page 21: 5800 Control Valve Assembly

    ..60705-06 ....DLFC, Plastic, 0.60 gpm If seal/spacer stack is stuck in valve bore during disassembly, CAUTION ..60705-08 ....DLFC, Plastic, 0.80 gpm rotate stack prior to removal... 60705-10 ....DLFC, Plastic, 1.0 gpm FLECK 5800 XTR2 Service Manual • 21...
  • Page 22: Turbine Meter Assembly - P/N 60626

    10 ....4 ..13314 ....Screw, Slot Ind Hex, 8-18 x 0.60 11 ....4 ..13305 ....O-ring, -119 12 ....1 ..14613 ....Flow Straightener 13 ....1 ..60086-50 ....Meter Assy, 3/4" Dual Port, Slip 22 • FLECK 5800 XTR2 Service Manual...
  • Page 23: Bypass Valve Assembly (Metal)

    Black Grip Lever, SS Not Shown: ..60041SS .....Bypass Valve, 5600, 1" NPT Black Grip Lever, Stainless Steel 2 ..19228-01 ....Adapter Assy, Coupling, w/O-rings Not Shown: 2 ..19228-01 ....Adapter Assy, Coupling, w/O-rings FLECK 5800 XTR2 Service Manual • 23...
  • Page 24: 2310 Safety Brine Valve

    ..60002-27 ....Air Check, #500, 27" Long ..60002-32 ....Air Check, #500, 32" Long ..60002-34 ....Air Check, #500, 34" Long ..60002-36 ....Air Check, #500, 36" Long ..60002-48 ....Air Check, #500, 48" Long 24 • FLECK 5800 XTR2 Service Manual...
  • Page 25: Water Conditioner Flow Diagrams

    WATER CONDITIONER FLOW DIAGRAMS Downflow 1. Service Position (Treatment) 4. Rapid Rinse Position (Rinse) 2. Backwash Position 5. Brine Tank Refill Position (Refill) 3. Brine/Slow Rinse Position (Draw) FLECK 5800 XTR2 Service Manual • 25...
  • Page 26 WATER CONDITIONER FLOW DIAGRAMS continued Upflow 1. Service Position (Treatment) 4. Rapid Rinse Position (Rinse) 2. Brine/Slow Rinse Position (Draw) 5. Brine Tank Refill Position (Refill) 3. Backwash Position 26 • FLECK 5800 XTR2 Service Manual...
  • Page 27: Dimensional Drawings

    DIMENSIONAL DRAWINGS Measurements inches 12.7 53.8 111.3 4.38 2.12 91.4 3.60 182.9 7.20 26.7 DISTRIBUTOR TUBE OD 1.05 BR61500-5800LNE Rev A FLECK 5800 XTR2 Service Manual • 27...
  • Page 28: Transformer Port Location

    Transformer port location (plugging in transformer) When looking at valve from front, reach around back under cover on right hand side. Transformer port is located just past the cover’s snap feature. 44288 REV A 28 • FLECK 5800 XTR2 Service Manual...
  • Page 29: Injector Flow Data

    INJECTOR FLOW DATA TR18755 Rev B FLECK 5800 XTR2 Service Manual • 29...
  • Page 30: Wiring Diagram

    Chlorine Generator can only be used with +12VDC power supply (international version only). +12VDC power supply with 5800, 5810, 5812 valves only. 30 • FLECK 5800 XTR2 Service Manual...
  • Page 31 FLECK 5800 XTR2 Service Manual • 31...
  • Page 32 P: 262.238.4400 | WATERPURIFICATION.PENTAIR.COM CUSTOMER CARE: 800.279.9404 | tech-support pentair.com For a detailed list of where Pentair trademarks are registered, please visit waterpurification.pentair.com. § Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners.

Table of Contents