Download Print this page

Programming Instructions - Pentair GOYEN IS Series Products Installation Instructions

Advertisement

10
Input Buttons: These buttons are used to control the menu and
program the controller.
11
Mode Switch: Use to change the controller between Continuous
Mode and dP Mode. (ISP only)
12
7-Segment LED: Display the menu and controller operation.
13
Interface Screen Socket (Optional): Ribbon cable socket for
the optional interface screen. Carefully insert the ribbon cable
securely into the socket and test the interface screen to confirm
it is functioning correctly.
14
Menu Interface LEDs: These show the status of the controller and
are used to indicate the setting during programing mode.
15
Power LED: When lit, it indicates the controller is powered ON.
16
dP Sensor: Connect the clean and dirty air lines to the sensor as
shown. (ISP only)
INTERFACE MODULE FUNCTIONS
Dem./Cont.
The Interface module comes standard with the enclosure and can be
ordered separately with the base board.
©COPYRIGHT Goyen Controls Co. Pty. Ltd.

PROGRAMMING INSTRUCTIONS

To enter Programming Mode:
On Time
Press Select
Off Time
The 'dP Low' LED should now be lit.
# Blowdown
Press Down
Run
The LED indicates the function to be programmed.
Press Up
Press Select
dP Low *
Press Select
This LED should start to flash indicating it is in programming mode.
dP Low
Use the Up
dP High
in demand mode, the cleaning cycle will stop at this setting.
dP Units
(Min. 00.0–Max. 03.8)
High dP Alarm
Press Select
On Time
Off Time
Press Down
# Blowdown
Run
dP High *
Press Select
This LED should start to flash indicating it is in programming mode.
Use the Up
in demand mode, the cleaning cycle will start at this setting.
(Min. 02.2–Max. 18.0)
Press Select
Press Down
* ISP only
2/56
PRODUCT INSTALLATION INSTRUCTIONS
GOYEN IS/ISP SERIES CONTROLLER
Power/Reset Button: This is used to turn the controller
ON and OFF and to conduct a Soft Reset. Once powered
ON using this button, the controller will relearn the
cleaning system. This button can be used to turn the
controller ON; however, the main power switch on
the base board must be in the ON position.
Press to scroll up through the menu.
Press to scroll down through the menu.
Press to enter settings.
Press to change between Demand or Continuous modes
(ISP only).
, Up
, Down
, Up
, Select
to scroll down the list.
to scroll up the list.
to change the settings for that function.
when the 'dP Low' LED is lit.
and Down
buttons to select a low dP limit. When
to confirm the setting. The 'dP Low' LED should now be lit.
to scroll down the list.
when the 'dP High' LED is lit.
and Down
buttons to select a high dP limit. When
to confirm the setting. The 'dP High' LED should now be lit.
to scroll down the list.