Fault Diagnosis - Mira Platinum Installation And User Manual

Digital shower
Hide thumbs Also See for Platinum:
Table of Contents

Advertisement

Fault Diagnosis

Read the section "Important Safety Information" first. As with most electronic equipment
resetting the digital mixing valve by powering it down waiting a few seconds then powering
it up again can often cure most issues.
Providing the digital mixing valve has been correctly installed and is operated in accordance
with the instructions contained in this guide, difficulties should not arise. If any maintenance
is required, then it must be carried out by a competent tradesperson. Before replacing any
parts make sure that the underlying cause of the malfunction has been resolved.
Warning! There are no user serviceable components beneath the cover of the
appliance. Only a competent tradesperson should remove the cover.
The digital mixing valve has built-in sensors to help diagnose system and product issues.
To access these advanced diagnostics features, please download the Mira Showers app
(see section "Set Up: Mobile App").
Please follow this self-diagnosis section to be sure the product is at fault before contacting Mira.
Diagnosis stage 1 (Error code check):
In the first instance, check your product has no error warning displayed on the controller.
You can also check for error codes on the Mira Showers app.
Only some errors are displayed on the controller. You will need to download the Mira Showers
app for full diagnosis and error functionality.
If you have an error code not listed below, or if the errors continue to occur after it has been
reset, please contact Mira customer services team to resolve the issue.
If you do not have an error code, proceed to Diagnosis stage 2
Error Code
3, 7, 9
4
11 or 111
37
55
Outlet temperature too hot. Try powering off the product for 30 seconds or resetting
in the Mira Showers app or using the controller menu option. Refer to diagnosis
section 4d.
Outlet thermistor not detected - contact Mira customer services team.
DO NOT ATTEMPT TO OPERATE YOUR PRODUCT. A temperature of less than
0°C has been detected in your product which could have caused internal damage
leading to potential leaks.
It is essential that your product is protected from freezing conditions otherwise
serious damage can occur.
Warning! If the valve module has been subjected to freezing conditions it
may require inspection to ensure internal damage has not occurred, (contact
your installer). If no sign of leaks, reset the product by powering off for 30
seconds or re-setting in the Mira Showers app or using the controller menu
option. Ensure there are no leaks when shower first used.
Hot water temperature spike detected - Turn off the product to maintain safety.
Check incoming water temperature is within specification and restart product.
Refer to diagnosis section 4d.
Description and remedial action