mIra moto, mIra pace,
mIra mInIlIte & mIra mInIdUo
thermostatIc mIxers
InstallatIon & User GUIde
These instructions must be left with the user.


Advertisement

Table of Contents
loading

Summary of Contents for Mira Mira Moto

  • Page 1 & mIra mInIdUo thermostatIc mIxers InstallatIon & User GUIde These instructions must be left with the user.
  • Page 2: Table Of Contents

    IntrodUctIon Introduction thank you for purchasing a quality mira product. to enjoy the full potential of your new product, please patents take time to read this guide thoroughly, having Safety Warnings done so, keep it handy for future reference.
  • Page 3 Mira Minilite EV Mira Moto EV Mira Miniduo EV Mira Pace EV  x concealing plates  x compression nuts...
  • Page 4: Safety Warnings

    WarnInGs mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided: 1. they are installed, commissioned, operated and maintained in accordance with manufacturers recommendations. 2. periodic attention is given, when necessary, Mira Minilite BIV to maintain the product in good functional order.
  • Page 5: Specifications

    0.1 Bar. (0. bar =  metre head from cold tank base to shower handset outlet). ü Note! For gravity fed / other low pressure moto (supplied fitted in systems (0.5 bar or below) remove the flow the outlet nipple) regulator(s).
  • Page 6: Dimensions

    Dimensions Mira Moto and Mira Minilite EV Mira Minilite BIV 56-76 39-59 Ø46 see Note! below Ø83 Mira Pace and Mira Miniduo EV Mira Miniduo BIV 56-76 53-73 Ø46 see Note! below all dimensions in mm Ø83 Note! If replacing an existing installation with pipework centres between 133 mm and 153 mm a universal retrofit accessory kit is available, refer to section: ‘Accessories’.
  • Page 7: Installation

    6. decide on a suitable position for the mixer. InstallatIon the position of the mixer and the shower Fittings must provide a minimum gap of 5 mm Suitable Plumbing Systems between the spill-over level of the shower tray/bath and the handset (refer to illustration). Gravity Fed: this is to prevent back-siphonage.
  • Page 8: Exposed Thermostatic Mixers

    Exposed Thermostatic Mixers For Built-in thermostatic mixers go to section: ‘Installation, Built-in Thermostatic Mixers’. Installing the Thermostatic Mixer 1. the thermostatic mixer can be installed with rear, rising or falling supply inlets. decide on the most appropriate method for your installation, and if necessary, loosen the grubscrews and rotate the inlet elbows to 39 mm...
  • Page 9 Flow regulator 23 mm from finished wall surface plug cap outlet nipple sealing plug COLD ‘o’ seal elbow 3 mm 0 mm recess Ø9 mm x  mm deep 6. Reverse Inlet Supplies Only: Using a suitable tool, carefully remove the 7.
  • Page 10 9. For Rear Entry Supplies Only: 15. Fit the shower fittings, refer to your shower fittings installation and user guide for Fit the concealing plates over the inlet instructions. pipes. Important! A 12 litre/minute flow regulator Note! apply silicone sealant to the back is fitted inside the outlet nipple.
  • Page 11: Installing The Built-In Thermostatic Mixer

    Installing the Built-in Thermostatic 4. determine the route for the hot and cold supply pipework and for the outlet pipework. Mixer When connecting to the BIV shower fittings it 1. carefully remove the concealing cap from the is recommended that the outlet be positioned control knob.
  • Page 12 6. Reverse Inlet Supplies Only: 8. carefully cut away the plasterboard and/or brick work to a depth of between 56 and 76 mm remove the sealing plug using the ‘o’ key from the finished wall surface. (supplied) or a  mm hexagonal key. Important! take care to stay within the marked remove the outlet nipple using the ‘o’...
  • Page 13 12. Insert the wall plugs (supplied) and attach 16. For solid wall installations go to instruction the mixer to the wall or timber noggin with the screws provided. For stud partition/laminated panel installations, 13. Fit the compression nuts and olives onto the finish the wall, then go to instruction 25.
  • Page 14 20. remove the assembly from the wall and separate the backplate from the wallplate. 21. For solid walls drill two 6 mm holes for the wall plugs. For other types of wall structure alternative fixings may be required (not supplied). If necessary, make a recess 6 mm deep to accept the wallplate for flush fitting of the outlet to the wall surface.
  • Page 15 concealing ring screws apply silicone sealant 32. Fit the concealing plate to the concealing ring. 33. Refit the control knobs. 34 Fit the shower fittings, refer to your shower fittings installation and user guide for instructions. Important! make sure that the  litre/minute flow regulator (supplied) is fitted under the hose washer (refer to illustration).
  • Page 16: Installing The Built-In Thermostatic Mixer  Commissioning

    .5 mm hexagon key (supplied) and pull off the control lever. 4. If applicable unscrew the hub retaining screw with a .5 mm hexagon key. Note! do not remove the hub. mira minilite / mira moto hub retaining screw mira miniduo / mira pace control lever...
  • Page 17: Operation

    Mira Moto and Mira Minilite thermostatic mixers have a single sequential control lever for on/off and temperature control. the control lever operates anti-clockwise in the following sequence: • • • cold • Warm • maximum preset temperature maximum preset...
  • Page 18: User Maintenance

    Lubricants User maIntenance silicone based lubricants must only be used on If you require a mira trained service engineer or the rubber seals. agent, refer to section: ‘Customer Services’. Caution! oil based or other lubricant types may cause rapid deterioration of seals.
  • Page 19: Notes

    notes...
  • Page 20 notes...
  • Page 21 notes...
  • Page 22: Spare Parts

    663.55 Flow regulator Filter pack (x) 663.58 outlet nipple 663.5 hub and Bearing assembly 663.56 control lever mira minilite and mira assembly (minilite) moto models only 663.50 control lever assembly (moto) 663.66 thermostatic cartridge assembly mira miniduo and mira pace models only 663.65...
  • Page 23 Built-in Models 663.54 elbow connector assembly 663.87 663.88 Backplate assembly elbow assembly 663.58 outlet nipple c, d 663.5 thermostatic cartridge assembly 663.60 663.5 outlet plug hub and Bearing assembly 663.55 663.56 Filter pack (x) control lever assembly (minilite) 663.86 concealing plate assembly 663.66 thermostatic...
  • Page 24: Customer Service

    Our Service Force is available to provide a quality service Damage or defects if the product is taken apart, repaired or at a reasonable cost. You will have the assurance of a Mira modifi ed by any persons not authorised by Mira Showers trained engineer/agent, genuine Mira spare parts and a or our approved agents.