Mira Platinum Installation And User Manual page 38

Digital shower
Hide thumbs Also See for Platinum:
Table of Contents

Advertisement

5
Fit the olive and compression nipple
over the outlet pipe and tighten the
compression nipple to 25 ± 1Nm.
Olive
7
DO NOT fit deluge head after pipework has been fully flushed through. Refer to
section "Commissioning".
for pumped product.
Screw the deluge head onto the shower arm by hand.
Note:
Use a suitably sized wrench to fully tighten (approximately 1/4 turn).
Caution! The shower arm is not designed to take weight, therefore care needs
to be taken when installing the deluge head.
Backplate
Compression Nipple
See page 43 for high pressure product, page 44
6
Fit the concealing shroud onto the
shower arm.
Fit the compression nut and olive onto
the shower arm.
Fit the shower arm into the compression
nipple and tighten the compression nut
to 25 ± 1Nm.
Hand tighten the concealing shroud
onto the backplate.
Olive
Concealing
Shroud
Shower Arm
Compression
Nut
Shower
Arm
Deluge Head
38

Advertisement

Table of Contents
loading

Table of Contents