Installer Maintenance; Fault Diagnosis - Mira Advance Standard J97I Installation And User Manual

Hide thumbs Also See for Advance Standard J97I:
Table of Contents

Advertisement

Installer Maintenance

Tradesperson Maintenance - Inlet Filter Cleaning/Replacing
Read the section 'Important Safety Information' first.
1. Electrical and water supplies to the
appliance are turned off.
3. Unscrew the filter cap. Remove,
clean and refit, or replace the filter
as necessary. Refit the filter and the
filter cap, making sure it is screwed
fully home.

Fault Diagnosis

1. Installer Troubleshooting Guide
Refer to section: 'Important Safety Information' first.
The following troubleshooting solutions may require the removal of the cover of the
shower. The cover should only be removed by a competent trades person and when
doing so they should be aware of the following:
Isolate the electrical and water supplies before initially removing the
cover.
Make sure Ribbon Cable is disconnected when removing the front
cover and reconnect when maintenance is complete.
2. Remove the cover screw, cover and
splash guard. Disconnect the ribbon
cable from the cover
4. Restore the water supply and check
for leaks. Re-prime the appliance
(refer to 'Installation') before
restoring the electricity supply. Refit
ribbon cable and cover.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advance flex j97k1.1759.003

Table of Contents