*Note:
Maintained (or dynamic) pressure is the pressure at the valve inlets during operation.
Some installations will see a significant pressure drop in the supply pipework when water is
flowing, especially when long plastic pipework and small bore fittings are used.
It is recommended to keep supply pipework as short as possible, avoid unnecessary bends
and minimise the number of fittings that are used. For longer pipe runs, it may be necessary to
increase the nominal pipe size to reduce the pressure drop. Consult a plumbing professional
if you are unsure.
If your plumbing system cannot maintain the minimum specified pressure at the valve inlets,
you will not be able to achieve the flow rates specified, even if you increase the flow rate
target of the product.
Electrical Rating
Supply Voltage
Maximum Load
Output Supply Voltage to Valve
Note:
Valves operating outside of the manufacturers recommended conditions of use cannot
be guaranteed to operate as TMV2 Type 2 valves.
User Control
Electrical Supply
Ingress Protection
Maximum Ambient Temperature
Plumbing Connections
Use below pipework size and type to make connections as listed.
Warning! Use of incorrect pipe types or sizes may cause leaks. Supplied connectors
are NOT suitable for 1/2" Pipework. You must use appropriate adapters (not supplied)
for 1/2" pipework.
Valve Inlet
Valve Outlet
Overhead (Ceiling Fed or Rear Fed Dual
Outlet products)
Handset supply pipe from valve (Ceiling Fed
product)
Right angled connector (Rear Fed product)
15
100V - 240V AC 50/60Hz
80W
12V DC & 24V DC
3.7Vdc Internal Battery (rechargeable)
IPX5
40°C
15mm Push fit Plastic or Copper (Isolator supplied)
15mm Push fit - see below (straight connector
supplied)
15mm Copper
15mm Push fit Plastic or Copper (Elbow supplied)
15mm Copper