Deluge Overhead - Mira Platinum Installation And User Manual

Digital shower
Hide thumbs Also See for Platinum:
Table of Contents

Advertisement

Installation: Deluge Overhead
A.
Rear Fed
The shower arm and deluge head should be fitted at a convenient height for all the family.
It should be positioned so that water sprays down over the centre of the bath, or away from
the opening of a shower cubicle.
1
The outlet pipe must protrude 18 mm
(± 2 mm) from the finished wall surface
and a minimum 35 mm from the ceiling.
Note:
Cut the pipe to the correct length
and remove any burrs.
2
Mark the positions of the backplate fixing
holes.
Caution! Be aware of hidden pipes or
cables.
3
For solid walls, drill the fixing holes for the
backplate with a 6 mm drill and insert the
wall plugs (supplied). For other types of
wall structure alternative fixings may be
required (not supplied).
4
Carefully fit the backplate over the outlet
pipe and secure with the fixing screws
(supplied).
Caution! Take care not to damage the
O Seal in the back of the backplate.
37
Minimum Distance to
Ceiling 35 mm
Note:
15mm copper pipe
must be used here.
Ceiling
18 ± 2 mm
Finished Wall