The SEMI Emergency OFF Switch carton contains:
6.4 Installing Your Robot
The TM Robot arm cannot stand independently after being removed from the carton. Therefore, prepare the
mounting base with the corresponding holes as described in 4.2.1.5 Robot Arm Installation, and follow the
instructions below to install the robot.
WARNING:
At the installation site, at least two people should simultaneously perform installation of the
robot; otherwise you risk robot arm damage or personal injury. Do not install the robot alone.
WARNING:
Do not attempt to move any robot links until the robot has been secured in position. Failure to
comply could result in the robot falling and causing either personnel injury or equipment
damage.
6.4.1 Remove the Control Box
After checking the contents, remove the contents in order and perform installation.
Control box carton:
Remove the Landmarks
Remove the power cable of the control box
Remove the control box (At least two people should remove the control box from the carton.
Refer the figure below for the correct holding positions.)
Connect the power cable to the control box
Place the control box near the robot base
Mount the control box in any direction (as long as the box is securely mounted), with a spacing
of at least 50 cm for the vents on both sides to facilitate cooling
Omron TM Collaborative Robot S Series: TM5S and TM7S Hardware Installation Manual
Table 18: The SEMI Emergency OFF Switch Carton Contents
SEMI Emergency OFF Switch
(SEMI series exclusive)
(1 pack)
Cable length: 300 cm
72