Communication / Reporting; Check Web Email; Email System Log; Start Direct Connect - Bosch Solution 6000-IP User Manual

Table of Contents

Advertisement

1. Enter [MENU] + [4] + [9] + [3].
If the system has multiple areas, the keypad will
display a list of areas.
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press

2. Use the [] and [] keys to select the area that
you want to test the fire sirens in, then press [OK].
Alternatively, you can enter the area number, then
press [OK].
The keypad will display the following during the fire
siren test.
Fire Audible Testing
Press any key to abort
Press OK or MENU
When the test is complete, the keypad will display
the following:
Testing Complete. Press
OK to continue
Press OK or MENU
3. Press [OK] to exit.

Communication / Reporting

Programming options in this section relate to how you
alarm system will communicate alarm information.
Your installer will advise you on the exact makeup and
configuration of your system.
Comms > Commands >

Check Web Email

Reserved for future use
Comms > Commands >

Email System Log

Reserved for future use
Comms > Commands >

Start Direct Connect

This menu allows the master user to start a direct link
session. You should discuss this option with your installer.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [0] + [5].
Bosch Security Systems 10/22 BLCC615U
OK or MENU
MENU 5-0-3
MENU 5-0-4
MENU 5-0-5
Comms > Commands >

Register Customer

This menu is used to enter the customer registration
number into the control panel. This unique 11 digit number
is generated by the system owner when they create an
account on MyAlarm web site.
This is required for panels using the MyAlarm iFob Control
App. See the MyAlarm website for more information at
www.myalarm.com.au.
Comms > Periodic Test >

Send Test Report

This menu allows you to test the reporting functions of the
control panel by manually sending a 'Test' report to the
receiving party (i.e. security company monitoring station
etc).
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [9] + [0].
The keypad will prompt that it is in the process of
sending a test report.
Comms Testing In
Progress ..Please Wait..
Press OK or MENU
If the test is successful, the keypad will prompt:
Comms Test Successful
Press OK or MENU
If the test is NOT successful, the keypad will prompt:
Test Report Failed..
Please Call For Service
Press OK or MENU
2. Press [OK] or [MENU] to exit.
Solution 6000-IP
User Guide
MENU 5-0-8
MENU 5-9-0
29

Advertisement

Table of Contents
loading