Basic System Operation; Turning An Area All On - Bosch CC610PB User Manual

Table of Contents

Advertisement

When you enter the premises through
a zone programmed for entry delay, the
Entry
keypad sound a Hi/Low tone to remind you
Delay
to turn off the area. If the area is not turned
Tone
off before the entry delay expires, an alarm
condition will sound and a report may be
sent to your alarm company.
After you turn an area All On, the keypad will
sound 1 short beep every second. During
Exit
the last 10 seconds fast short beeps will be
Delay
heard. If you don't exit before the delay time
Tone
expires and an exit delay door is faulted, an
alarm occurs.
If you enter an incorrect value when
Error
programming, the keypad will sound a 2
Tone
second tone.
The keypad will sound a Lo/Hi tone to
Menu
indicate you have entered MENU Mode and
Mode
a Hi/Lo tone to indicate you have exited
MENU mode.
The keypad sounds fast short beeps to alert
Chime
you when a zone programmed for chime is
Tone
faulted or unsealled.
Table 4: Keypad Tones and Their Meanings
Figure 2: CP736B 3.5" Graphic Keypad
B a si c Syste m Ope rat ion

Turning An Area All On

Use this function to turn an area All On. The control panel
is factory defaulted for one area. As soon as you turn an
area on, exit time will start. Exit time allows you to exit
the premises without sounding an alarm. Your security
company or a master PIN user can program the length of
exit delay time.
Bosch Security Systems 3/23 BLCC610U
1. Make sure that all zones are normal (not faulted).
2. Enter your PIN, then press the [ON] key.
If your PIN is valid and if all zones are normal, exit delay
time will start. You should leave now. If your control
panel detects a faulted zone, you should return it to
normal, or bypass the zone.
During exit delay, you may stop the area from turning
on by entering your PIN followed by the [OFF] key.
3. To turn the system (or area) off, enter your PIN, then
press [OFF].