7-INSTALLATION

7.1 Operating Conditions

(see Section 4).
7.2 Space Requirements for Machine Operation
and Maintenance Work
Minimum distance from wall (Figure 7-1):
A = 1.0m. (39.4 inches)
B = 0.7m. (27.6 inches)
Minimum height = 2.7m. (106.3 inches)
WARNING
To reduce the risk associated with
mechanical and electrical hazards:
Read, understand, and follow all safety and
operating instructions before operating or
servicing the case sealer.

7.3 Tool Kit Supplied with the Machine

A tool kit containing some tools are supplied
with the machine. These tools should be
adequate to set-up the machine, however,
other tools supplied by the customer will be
required for machine maintenance.
a20-NA
Figure 7-1
7.4 Machine Positioning / Bed Height
Figure 7-2
WARNING
To reduce the risk associated with
muscle strain:
Use the appropriate rigging and material
handling equipment when lifting or
repositioning this equipment.
Use proper body mechanics when
removing or installing taping heads that are
moderately heavy or may be considered
awkward to lift.
1 - Lift the machine with belts or ropes paying
attention to place the belts in the points (Figure 7-2).
To set the machine bed height, do the following:
2 - Adjust machine bed
height. The case
sealer is equipped
with four adjustable
legs that are located
at the corners of the
machine frame.
The legs can be
adjusted to obtain
different machine
bed heights
(Figure 7-3).
Also refer to the
"Specifi cations"
section.
3 - Lock the screws.
4 - Repeat the
operation for all legs.
(It is not necessary
to fi x or anchor the
machine to the fl oor).