Problems At Power-On Initialization (Part 004/4); Problems Related To Printing (Part 001/2) - Fujitsu ULTIMA90 Maintenance Manual

Dot matrix printer
Table of Contents

Advertisement

3.1.1 Problems at power-on initialization (part 004/4)

4 [LED type]
The PAPER OUT lamp
blinks.
[LCD type]
Error message blinks.

3.1.2 Problems related to printing (part 001/2)

1 The POWER lamp
goes off during printing.
Then, turn the power
switch OFF, and turn
on the power after 10 to
20 seconds.
However, the POWER
lamp does not go on.
Fire check alarm of ribbon feed
motor [LED type]
Also
REMOVE
PAPER
MENU2 lamps blink.
[LCD type]
LCD displays as follows
FATAL!
RBFM ALARM
Symptom
FAN alarm
[LED type]
Also REMOVE PAPER and CUT
SHEET lamps blink.
[LCD type]
LCD displays as follows
FATAL!
FAN ALARM
SPACE alarm
[LED type]
Also REMOVE PAPER and
TRACTOR R lamps blink.
[LCD type]
LCD displays as follows
FATAL!
SPACE ALARM
HCPP alarm
[LED type]
Also FRONT DIR and
TRACTOR R lamps blink.
[LCD type]
LCD displays as follows
FATAL!
HCPP ALARM
Symptom
+40 V over voltage alarm
Ribbon motor alarm is
detected.
and
A. The RF motor
connector is
disconnected.
B. The RF motor is
defective.
C. The control board is
defective.
Cause
FAN motor alarm is
detected.
A. The FAN motor
connector is
disconnected.
B. The FAN motor is
defective.
C. The control board is
defective.
Space alarm is detected.
A. The SP motor
connector is
disconnected.
B. The SP motor is
defective.
C. The stay shaft is
rough.
D. The SP belt is loose.
E. The control board is
defective.
• HCPPSW ASY is
defective.
• The HCPP motor is
defective.
• HCPPSW ASY is
not connected.
• The control board is
defective.
Cause
The power supply is
faulty.( The power
supply is a high
voltage.)
18
A. Connect the
Connector correctly.
B. Replace the RF motor.
C. Replace the control
board, then initialize
the EEPROM.
Response
A. Connect the
Connector correctly.
B. Replace the FAN
motor.
C. Replace the control
board, then initialize
the EEPROM.
A. Connect the
Connector correctly.
B. Replace the space
motor.
C. Clean or lubricate the
stay shaft.
D. Check the tension
pulley.
E. Replace the control
board, then initialize
the EEPROM.
• Replace the
HCPPSW ASY.
• Replace the HCPP
motor.
• Connect the
HCPPSW ASY cable
properly.
• Replace and initialize
the control board.
Response
Replace the power supply
unit.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultima90 +Impact4550 proDl7600

Table of Contents