Changing The Setting Value - Omron ZN-DPX21-S Series User Manual

Differential pressure station, thermo-humidity station, air thermo logger
Table of Contents

Advertisement

(3) Adjusting humidity
The humidity measurement value is displayed in the upper line, and the value after adjustment
in the lower line.
The value will not be adjusted if in the lower line you set the value after adjustment to the
same as the value currently displayed in the upper line. If a different value is set, the
difference between the values in the upper line and the lower line will be added to the
measured value as an offset. The adjustment range is ±10.0 °C.
When adjustment has been set, "SCL" is ON during measurement in RUN mode.
Setting range (numeric value input type):
-10.0 % (Displayed value in the upper line) to +10.0 % (Displayed value in the upper line)
Initial value:
The same value as the measured value (not adjusted)

4.4.5 Changing the setting value

Change the value in the same way as changing the settings in FUN mode.
Refer to: 4.2.5 Changing the setting value