Table 15. Temperature, humidity, and altitude specifications (non-operating - long term)
Non-operating - long term (unpacked or packed)
Dry Bulb Temperature
Temp Gradient
Temperature Shock
Wet Bulb Temperature
Relative Humidity
Humidity Gradient
Altitude (sea level)
Table 16. Temperature, humidity, and altitude specifications (transit - short term)
Transit - short term (packed 7 days)
Dry Bulb Temperature
Temp Gradient
Temperature Shock
Wet Bulb Temperature
Relative Humidity
Altitude (sea level)

Shock

The following tables provide operating, non-operating, transit/storage, and
physical drop test shock specifications for the 4560SLX Tape Library.
Table 17. Shock specifications (operating)
Operating (within spec - no damage)
Peak Acceleration
Duration
Waveshape
Application
Table 18. Shock specifications (non-operating)
Non-operating (unpacked - no damage)
Peak Acceleration
Duration
Waveshape
Application
Get other manuals https://www.bkmanuals.com
-40°C to 60°C
20°C/hr. (across the range)
15°C (over 2 min.)
30°C
5% to 95% (non-condensing)
10%/hr
-1000 ft. to +10,000 ft.
-40°C to 60°C
25°C/hr. (across the range)
15°C (over 2 min.)
30°C
5% to 95% (non-condensing)
-1000 ft. to +10,000 ft.
1.5 G's
11 ms
1/2 sine pulses
X,Y,Z axes, repeat 3 times
25 G's
11 ms
1/2 sine pulses
X,Y,Z axes, repeat 3 times