Oven On Indicator Light Removal; Iris Module Removal; Surface Burner Valve Removal - Viking VGCC530 Service Manual

Hide thumbs Also See for VGCC530:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Oven On Indicator Light Removal

Condition Requirements:
Control Components Accessed
1. Hold the red lens and slide off the indicator light. The
indicator light will only slide in one direction.
2. Disconnect two connectors from the indicator light.
3. Reverse procedure for installation.

IRIS Module Removal

Condition Requirements:
Control Panel Assembly Removed
1. Disconnect connectors from module.
2. Pull to remove module from burner valve.
3. Reverse procedure for installation.
©2009 Viking Preferred Service

Surface Burner Valve Removal

Condition Requirements:
Control Panel Assembly Removed
Gas Shut Off
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove two screws that secure manifold assembly
to range.
2. Pull to remove spark module from burner valve.
3. Remove fl ex tubing from burner valve.
4. Remove screw and burner valve from manifold
assembly.
5. Reverse procedure for installation.
6. Perform gas leak test.
Disassembly
27

Advertisement