Control Components Accessed

Condition Requirements:
Door Assembly Removed
1. Remove all surface burner knobs.
2. Remove screws from control panel assembly where
knobs have been removed.
3. Remove screws from below control panel assembly.
4. Lift up to remove control panel assembly from two
keyhole screws.
5. Place control panel assembly on protective surface
on the top of range.
6. Reverse procedure for installation.

Control Panel Assembly Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect all connectors to remove control
panel from range.
2. Reverse procedure for installation.
©2010 Viking Preferred Service

Indicator Light Removal

Condition Requirements:
Control Components Accessed
1. Hold the blue lens and slide off the indicator light.
The indicator light will only slide in one direction.
2. Disconnect two connectors from the indicator light.
3. Reverse procedure for installation.

Oven Control Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect connectors from the oven
control.
2. Remove screws and oven control from the control
panel assembly.
3. Reverse procedure for installation.

Convection Fan Switch Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect connectors from fan switch.
2. Remove screws and convection fan switch from
control panel.
3. Reverse procedure for installation.
Disassembly