Bake/Broil Gas Shutoff Valve Removal; Orifi Ce Removal; Burner Base Assembly Removal - Viking VGCC530 Service Manual

Hide thumbs Also See for VGCC530:
Table of Contents

Advertisement

Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Bake/Broil Gas Shutoff Valve Removal

Condition Requirements:
Control Panel Assembly Removed
Gas Shut Off
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove two screws that secure manifold assembly
to range.
2. Pull to remove module from burner valve.
3. Remove tubing from shutoff valve.
4. Remove screw and shutoff valve from manifold
assembly.
5. Reverse procedure for installation.
6. Perform gas leak test.
28
Orifi ce Removal
Condition Requirements:
None
1. Remove grates, burner cap, and burner head from
burner base assembly.
2. Remove orifi ce from jet holder.
3. Reverse procedure for installation.

Burner Base Assembly Removal

Condition Requirements:
None
1. Remove grates, burner cap, and burner head from
burner base assembly.
2. Remove two screws and lift burner base assembly
from range.
3. Disconnect wire from burner base assembly.
4. Reverse procedure for installation.
©2009 Viking Preferred Service

Advertisement