To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Gas Solenoid Valve Removal
Condition Requirements:
Main Top Removed
Gas Supply Disconnected
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove screw and position jet holder bracket out of
way.
2. Mark and disconnect two wires from solenoid coil.
3. Remove two gas tubes from solenoid valve.
4. Remove two screws and solenoid valve from range.
5. Reverse procedure for installation.
6. Perform gas leak test.
©2009 Viking Preferred Service
Manifold Assembly Removal
Condition Requirements:
Main Top Removed
Gas Supply Disconnected
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove all IRIS modules from valves.
2. Disconnect fl ex tubing from each valve.
3. Disconnect tubing from shutoff valve.
4. Remove three screws and manifold assembly from
range.
5. Reverse procedure for installation.
6. Perform gas leak test.
Disassembly
31