Broil Burner Igniter Removal; Oven Control Removal; Direct Spark Module Removal; Door Switch Removal - Viking VGCC530 Service Manual

Hide thumbs Also See for VGCC530:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Broil Burner Igniter Removal

Condition Requirements:
Door Assembly Removed
1. Remove two screws and pull igniter wire into oven
cavity.
2. Disconnect wire to remove igniter from range.
3. Reverse procedure for installation.

Oven Control Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect four connectors from the oven
control.
2. Remove two screws, bezel, and the oven control
from the control panel assembly.
3. Reverse procedure for installation.
©2009 Viking Preferred Service

Direct Spark Module Removal

Condition Requirements:
Control Components Accessed
1. Remove three screws and slide component tray
forward.
2. Mark and disconnect four connectors from direct
spark module.
3. Remove four screws and direct spark module from
component tray.
4. Reverse procedure for installation.

Door Switch Removal

Condition Requirements:
Control Components Accessed
1. Remove two screws and door switch from range.
2. Mark and disconnect two connectors from door
switch.
3. Reverse procedure for installation.
Disassembly
25

Advertisement

Table of Contents
loading

Table of Contents