Backguard Assembly Removal - Viking VGCC530 Service Manual

Hide thumbs Also See for VGCC530:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Backguard Assembly Removal

Condition Requirements:
Rear of Range Accessed
1. Remove four screws and backguard assembly from
range.
2. Place backguard assembly on suitable work surface.
3. Remove 17 screws and back.
4. Remove inner diverter.
©2009 Viking Preferred Service
5. Remove six screws, end caps, and top from front
support.
6. Remove fi ve screws and slide front support from front
panel.
Note:
Pry corner of front panel slightly to allow front
support to slide from the front panel.
7. Reverse procedure for installation.
Disassembly
29

Advertisement