Control Components Accessed; Indicator Light Removal; Control Panel Assembly Removal; Oven Control Removal - Viking VGIC530 Service Manual

30 & 36 inch gas range
Hide thumbs Also See for VGIC530:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Control Components Accessed

Condition Requirements:
None
1. Remove all surface burner knobs.
2. Remove screws and bezels from control panel
assembly where knobs have been removed.
3. Slide drip tray out and place protective cover on drip
tray.
4. Lift up to remove control panel assembly from four
keyhole screws.
5. Tilt control panel assembly forward rest on drip tray.
6. Reverse procedure for installation.

Indicator Light Removal

Condition Requirements:
Control Components Accessed
1. Hold the red lens and slide off the indicator light. The
indicator light will only slide in one direction.
2. Disconnect two connectors from the indicator light.
3. Reverse procedure for installation.
©2010 Viking Preferred Service

Control Panel Assembly Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect all connectors to remove control
panel from range.
2. Reverse procedure for installation.

Oven Control Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect connectors from the oven
control.
2. Remove screws, bezel, and the oven control from the
control panel assembly.
3. Reverse procedure for installation.