2.3 Electrical Specifications
Power
Residual ripple
Power over Ethernet
Ethernet
Connection
LED
Input
Digital
Ground
Output
Digital
Ground
24 VDC, ± 20%, max 15 W (via M16 socket)
≤ 500 mV (peak-to-peak)
IEEE 802.3at, mode A or B, mixed DC & data
M12 socket, 8 wires (full duplex)
10/100/1000 Mbit/s, 1000BASE-TX, Auto-Negotiation
electrically isolated from power supply
multi-color indicator, see section 6.2
3x inputs
high signal with 4.5 - 24 V, 4 mA
low signal with < 2.0 V, 1 mA
common ground connection for all inputs
electrically isolated to GND Power and housing ground (4500 V
3x outputs
Open-Drain
max. VDC = + 24 V, 100 mA
or
Pull-up
0 V / 5 V, max. 7 mA
common ground connection for all outputs
electrically isolated to GND Power and housing ground (2500 V
LED Status
Indicator, page 32
rms
rms
Technical Data
Electrical Specifications
)
)