Fluke TiX660 User Manual

Fluke TiX660 User Manual

Thermal imager
Hide thumbs Also See for TiX660:
Table of Contents

Advertisement

Quick Links

TiX620, TiX640, TiX660,
TiX1000
Thermal Imager
September 2014, Rev.1, 9/16
© 2014, 2016 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
GlobalTestSupply
www.
.com
Find Quality Products Online at:
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

Summary of Contents for Fluke TiX660

  • Page 1 TiX620, TiX640, TiX660, TiX1000 Thermal Imager September 2014, Rev.1, 9/16 © 2014, 2016 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for two years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Chapter Title Page Before You Start ......................1-1 Introduction ........................1-1 How to Contact Fluke ..................... 1-2 Safety Information ......................1-3 Optional Accessories ...................... 1-7 Technical Description ..................... 1-7 Functional Principle ....................1-7 Description of the Functional Units ................1-7 Lens ........................
  • Page 4 TiX620, TiX640, TiX660, TiX1000 Users Manual Parts of the Thermal Imager ..................1-16 Quick Guide ........................1-18 Preparation ....................... 1-19 Start .......................... 1-19 Display ........................1-20 Setting the Focus ...................... 1-21 Setting the Temperature Range ................1-21 Saving Images ......................1-24 Saving with "Check"...
  • Page 5 Contents (continued) ® LaserSharp Auto Focus ................... 2-8 ® Permanent LaserSharp Auto Focus ................. 2-8 EverSharp Multifocal Recording ................2-8 Spot Editor ........................2-9 Saving ..........................2-9 Saving with Check ......................2-10 Quick Saving ........................2-10 Display Menus ......................3-1 Introduction ........................
  • Page 6 TiX620, TiX640, TiX660, TiX1000 Users Manual GPS Submenu ......................3-35 Laser Submenu ......................3-35 Settings Menu ........................ 3-36 Calibration Submenu ....................3-36 Extras Submenu ....................... 3-37 Automatic Submenu ....................3-38 Compensation Submenu ..................3-39 Buttons Submenu ..................... 3-40 Digital Alarm Output Submenu.................. 3-43 Configuration Submenu ....................
  • Page 7: Before You Start

    The thermal imager is equipped with a digital color video Introduction camera in order to document the measuring situation on The TiX620, TiX640, TiX660, and TiX1000 Thermal photos. Infrared (IR) and visual light images, as well as Imagers (the Product) are state-of-the-art thermography...
  • Page 8 TiX620, TiX640, TiX660, TiX1000 Users Manual Typical fields of application of the thermography system are: • thermographic inspection of electrical and mechanical systems • optimization of components and assemblies • material inspections • control of process temperatures • quality assurance •...
  • Page 9: Safety Information

    Before You Start Safety Information Safety Information • The Product is equipped with an LED light to illuminate the image. Avoid any A Warning identifies conditions and procedures that are direct eye contact and do not point the dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or LED light at people, animals, or reflective the equipment under test.
  • Page 10 TiX620, TiX640, TiX660, TiX1000 Users Manual • • Do not use the Product around explosive Remove the batteries if the Product is gas, vapor, or in damp or wet not used for an extended period of time, or if stored in temperatures above 50 °C.
  • Page 11 For safe operation and maintenance of the Product: • Repair the Product before use if the battery leaks. • Be sure that the battery polarity is correct to prevent battery leakage. • Use only Fluke approved power adapters to charge the battery.
  • Page 12  disposed of by a qualified recycler or hazardous materials handler per local regulations. Contact your authorized Fluke Service Center for recycling information. This product complies with the WEEE Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With ...
  • Page 13: Optional Accessories

    Before You Start Optional Accessories Optional Accessories Technical Description • ac adapter with 14-pin LEMO connector Functional Principle • The Product is a thermography system designed for the replacement lenses, macro attachments long-wave infrared spectral range (LWIR) of 7.5 μm to •...
  • Page 14 TiX620, TiX640, TiX660, TiX1000 Users Manual Table 1-2 is a list the optional lenses that are available for TiX640, TiX660, and TiX1000: Table 1-2. Thermography System Lenses 1024 x 768 640 x 480 Focal IFOV Model Lens distance Focus (m) FOV (°)
  • Page 15 Before You Start Technical Description Table 1-2 is a list the optional lenses that are available for the TiX620: Table 1-3. Thermography System Lenses - TiX620 640 x 480 Minimum Focus Model Lens Focal distance IFOV (mrad) FOV (°) (mm) (mm) IR 1/10 Wide angle...
  • Page 16: Detector

    TiX620, TiX640, TiX660, TiX1000 Users Manual Detector Image Processing Electronics The thermal imager is equipped with an uncooled With the help of an FPGA (Field Programmable Gate microbolometer FPA detector (uncooled Focal Plane Array) and up to two processors, real-time image...
  • Page 17: Optomechanics

    Before You Start Technical Description Specific modes of camera operation and presettings can Optomechanics be configured using menus. Chapter 2 contains a detailed With the help of an optomechanic assembly, the following description of how to operate the thermography system, functions are implemented: as well as a detailed description of the menu structure.
  • Page 18: Interfaces

    2 x analog output 0-5V (LEMO 14-pin) Measurement accuracy • RS232 (LEMO 14-pin) TiX640, TiX660, TiX1000 .... ±1.5 K or ±1.5 % • GigE-Vision (LEMO 8-pin) TiX620 ........±2.0 K or ±2 % Simultaneously using several interfaces on the 14-pin LEMO socket is allowed for by means of a breakout box.
  • Page 19 Battery ........Standard lithium-ion video Dimensions with standard 30 mm lens camera battery TiX1000, TiX660 ......210 mm x 125 mm x 155 mm Operating temperature (8.25 in x 4.9 in x 6.1 in) with external power ....-25 °C to +55 °C TiX640, TiX620 ......
  • Page 20 TiX620, TiX640, TiX660, TiX1000 Users Manual Weight with standard 30 mm lens Features: ® TiX1000, TiX660 ......1.95 kg (4.3 lb) • Fluke Connect compatible • AutoBlend™ mode TiX640 ......... 1.4 kg (3.1 lb) • ® LaserSharp Auto Focus (TiX660, TiX1000 only) TiX620 .........
  • Page 21: Unpacking And Control

    • ac adapter • integrated digital color video camera • depending on the equipment, Laser Distance Meter/laser pointer, GPS • rechargeable lithium-ion battery NP-QM91D (Sony) (2 with TiX660, TiX1000; 1 with TiX640, TiX620) • battery charger • SDHC card 1-15...
  • Page 22: Parts Of The Thermal Imager

    Item Description Multifunction button Connection for power supply, trigger, FBAS   Handle SD card slot   Color TFT viewfinder (TiX660, Tix1000 only) USB port   Lithium-ion battery DVI port   Connection for GigE-Vision, RS232  1-16...
  • Page 23 Before You Start Table 1-5. Front View of Thermal Imager Item Description Color Video Camera  Lens  Laser Range Finder  LED Video Light  Color TFT Display  hvh014.eps 1-17...
  • Page 24: Quick Guide

    TiX620, TiX640, TiX660, TiX1000 Users Manual Quick Guide Table 1-6 shows the location of the controls on your thermal imager. In order to achieve professional results, we recommend thoroughly reading the entire manual. Table 1-6. Control Locations Item Description Focus rocker switch with autofocus ...
  • Page 25: Preparation

    Remove the protective cap from the lens. • thermal imager • rechargeable lithium-ion battery or ac adapter with Push . The imager turns on and the Fluke logo displays during the boot process. At system LEMO connector initialization the power-on LED initially flashes green ®...
  • Page 26: Display

    TiX620, TiX640, TiX660, TiX1000 Users Manual Display Table 1-7 shows the location of the display elements. Table 1-7. Arrangement of the Image Elements hvh022.eps Item Description Item Description Camera menu Rechargeable battery, SDHC card   Temperature unit Status indications ...
  • Page 27: Setting The Focus

    Before You Start Quick Guide Initially, you must view a scene that contains a thermal Setting the Temperature Range contrast, for example, an active electrical device. Then Push  with a short press. The thermography system point the thermal imager at this scene. automatically sets a temperature scale of the false color image corresponding to the current scene: To use the viewfinder, fold the display to the side of the...
  • Page 28 TiX620, TiX640, TiX660, TiX1000 Users Manual Depending on the selected input variant, the joystick  as well. In this, the respective joystick and button functions are displayed to the left of the thermal image. can be used in order to set the temperature level and the...
  • Page 29 Before You Start Quick Guide If you manually set the options Level/Range and temperature scale automatically (AUTO mode). In AUTO Maximum/Minimum, you can set the temperature scale mode,  shows on the right side of the image above  the color palette. The AUTO mode is terminated by any one time, automatically, with a short push of Enter manual setting of Level/Range/Max/Min.
  • Page 30: Saving Images

    TiX620, TiX640, TiX660, TiX1000 Users Manual Saving Images Quick Saving In order to save the thermal image, the  button is Immediately push the  button completely. The image is required. The following variants are possible: saved immediately:  , the camera control then automatically re-activates the Live mode: ...
  • Page 31: Menu Functions

    Before You Start Quick Guide  Sub-menus can be opened by using the button (Enter) Menu Functions on the respective menu item, for example, push the The thermal imager offers a large number of analysis and button in order to open the sub-menu for automatic functions and can be configured individually for manually setting the temperature range.
  • Page 32: Data Transmission To The Computer

    (1/4") tripod thread (DIN 4503) on the bottom of the protection of the device. housing. To achieve rigid camera images, particularly for the SuperResolution mode, Fluke recommends that you attach the thermal imager to a tripod.  Caution Do not exceed the maximum penetration depth of the tripod thread: 4.5 mm (DIN...
  • Page 33: Lens Replacement

    Before You Start Set-Up Lens Replacement Operation using the Gigabit Ethernet (GigE) Interface Only replace the lenses in dry and low-dust conditions. IP 54 When the lens is removed, the degree of protection Please proceed as follows in order to connect the thermal of the system is no longer guaranteed! imager to a PC/notebook.
  • Page 34: Ethernet Cable And Ac Adapter

    TiX620, TiX640, TiX660, TiX1000 Users Manual Ethernet Cable and AC Adapter AC Adapter Connection The Ethernet cable is used in order to connect the To operate while permanently connected to a notebook or thermography camera to the 8-pin LEMO socket (left- PC, the power should be supplied using the ac adapter hand side, blue mark).
  • Page 35 Before You Start Set-Up  Caution Connect the breakout box to the COM interface of the host computer with a commercially available Follow the specified steps on how to cable. establish the required connections. Connect the supplied ac adapter to the breakout box. Connect the thermography camera to the breakout box.
  • Page 36 TiX620, TiX640, TiX660, TiX1000 Users Manual 1-30...
  • Page 37: Elements Of The User Interface

    Chapter 2 Elements of the User Interface Introduction Note All buttons can be used for multiple functions The thermal imager has these controls (see Table 2-1): triggered either by: • keyboard on the right top camera side (focus rocker • half or full pressing: ...
  • Page 38 TiX620, TiX640, TiX660, TiX1000 Users Manual Table 2-1. Control Locations Item Description Focus rocker switch with autofocus   Temperature   Auto   Multifunction 2   Multifunction 1   Save    Joystick  Power ...
  • Page 39: Button Functions

    Elements of the User Interface Button Functions Button Functions The functions are assigned (factory defaults) to the function buttons in such a way that functions required frequently can be executed quickly: Table 2-2. Shortcuts Button Type Function Explanation short Auto Mode (Span) Automatic adaptation temperature scale ...
  • Page 40 TiX620, TiX640, TiX660, TiX1000 Users Manual The function of the save button  when saving images is The Power button is used to turn on the thermal  defined in the Saving Format Submenu (see Chapter 3, imager. Initially, the status LED on the left-hand side Menus).
  • Page 41: Image Elements

    Elements of the User Interface Image Elements Image Elements The image elements have the following functions: Table 2-3. Image Elements Image Element Location Function Image Central display area Display of the current thermal image, visual light image or of a superimposition of both images, display of saved images Menu Left from screen area...
  • Page 42 TiX620, TiX640, TiX660, TiX1000 Users Manual Table 2-3. Image Elements (cont.) Image Element Location Function Status symbols Lower screen area, right Status indicators for: • power supply (ac adapter/status rechargeable battery) • SDHC card • laser distance meter/laser pointer •...
  • Page 43: Setting The Temperature Scale

    Elements of the User Interface Setting the Temperature Scale In addition to the current temperature scene in false color Setting the Temperature Scale representation, different image elements are used in At system start (pushing the power button ), the order to show information about the camera status and camera is in Live mode.
  • Page 44: Lasersharp ® Auto Focus

    TiX620, TiX640, TiX660, TiX1000 Users Manual Use the focus rocker switch  to:  Warning To prevent eye damage and personal injury: • Manual focus • Do not look into the laser. Do not point push the left side of the focus rocker switch in...
  • Page 45: Spot Editor

    Elements of the User Interface Spot Editor Saving Spot Editor Thermography images and photographic pictures are By pushing the  button, a temperature measuring point saved to the SC card inserted into the camera. The is created in the center of the image. Pushing the  thermal imager supports commercially available SD button with the spot turned on will turn off the measuring and/or SDHC cards up to a capacity of 32GB.
  • Page 46: Saving With Check

    TiX620, TiX640, TiX660, TiX1000 Users Manual Saving with Check Quick Saving To check the image to be recorded before saving it, the Using the thermal imager, you can immediately save Live mode should be stopped: images in the Live mode or directly from the motion: •...
  • Page 47: Display Menus

    Chapter 3 Display Menus Introduction  The menu can be navigated using the joystick settings are accepted using the joystick center button The main menu is designed to select and set the different (Enter). The four main menus are located on the upper functions of the thermal imager.
  • Page 48: Image Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual  Image Submenu Within the menus, the joystick is used to navigate to the top ↑ and/or to be bottom ↓. The main menus can be The Image menu constitutes a summary of the settings switched using the buttons and →.
  • Page 49: Manual Submenu

    Display Menus Image Submenu Manual Submenu Different modes can be selected for manually setting the The option of manually setting the temperature scale is a temperature range in the "Manual" menu item: central function of each thermography camera. Therefore, this function is arranged in a quickly accessible menu in •...
  • Page 50 TiX620, TiX640, TiX660, TiX1000 Users Manual Depending on the selected input variant, the joystick  as well. In this, the respective joystick and button functions are displayed to the left of the thermal image. can be used in order to set the temperature level and the...
  • Page 51: Mode Submenu

    Display Menus Image Submenu Along with the option of manually setting the temperature Mode Submenu scale, the temperature scale can be set once by pushing In Live mode, the thermal imager displays thermal images the joystick Enter button shortly, or permanently active, by (infrared images), video images (Digital images), or the pushing the joystick Enter button longer.
  • Page 52 TiX620, TiX640, TiX660, TiX1000 Users Manual Digital image mode Infrared Image Mode In the Digital image mode, the camera-internal digital In the Infrared Image mode, the thermal image is shown photo channel is operated in video mode and displayed in false color representation. Depending on the with a geometric resolution of (1024 x 720) pixels.
  • Page 53 Display Menus Image Submenu Color Alarm ® ® IR Fusion with Autoblend Technology In the Color Alarm mode, a (partial) temperature interval (Picture-in-Picture) is defined within the set temperature range. Partial areas, In the Picture-in-Picture mode, a part of the infrared the temperatures of which are within this interval, are image is superimposed over the digital image, regardless displayed as an infrared image in false color...
  • Page 54: Zoom Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual High Alarm, Low Alarm Zoom Submenu Just as in Interval, a (partial) temperature interval is Depending on the equipment, the thermal imager defined in the High Alarm and Low Alarm modes, not only supports digital magnification of the infrared image and the upper and/or lower limits are defined for the partial the Digital image (visible light image) up to 32-fold.
  • Page 55: Palette Submenu

    Display Menus Image Submenu Palette Submenu The current allocation of the individual colors/shades of gray of the false color representation to the corresponding temperatures is performed by using the palette shown on the right-hand side margin of the screen. In this, the maximum value of the image area above and its minimum value below the palette serve the purpose of orientation for the temperature level.
  • Page 56 TiX620, TiX640, TiX660, TiX1000 Users Manual Table 3-1. Palettes Palette containing 256 colors Grayscale/Rainbow palette with Grayscale palette (left) and (left) and 16 colors (right) temperature-linear (left) and Ultra inverted representation (right) Contrast representation 3-10...
  • Page 57 Display Menus Image Submenu The "Inverse" function can be used to invert the current On the left-hand side, the palette with temperature-linear palette. For example, if the grayscale palette is set, the representation is shown. On the right-hand side, the low temperatures are indicated in darker colors when palette with logarithmic representation of the temperature compared to the higher temperatures by default.
  • Page 58: Elements Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual Elements Submenu The "Elements" menu item can be used to individually adapt the user interface by selecting the individual image elements. The menu comprises the two submenus "Elements" and "Hide". The "Elements" submenu can be used to open the "Image elements"...
  • Page 59: Isotherms Submenu

    Display Menus Image Submenu the same temperature (in a defined temperature interval) Isotherms Submenu with the same representation color and/or shade of gray. In the "Image" menu using the "Isotherms" menu item, With the help of the isotherms editor, it is possible to the isotherms editor can be started and/or settings for create isotherms for differently sized temperature already created isotherms can be made, or all isotherms...
  • Page 60 TiX620, TiX640, TiX660, TiX1000 Users Manual Along with the definition of Intervals for isotherms, dialog. At this point, changing the color of the isotherm is identifying temperatures over or under a certain limit is also possible. The 15 "special colors" designed for the possible.
  • Page 61: Filter Mode Submenu

    Depending on the model, a different number of partial image formats are available. Note This feature is an option. Fluke recommends that you order the feature at the time of hvh157.jpg purchase. Otherwise, you must return the imager to the manufacturer for installation.
  • Page 62: File Menu

    TiX620, TiX640, TiX660, TiX1000 Users Manual 100 = 67,600 files will have been saved to File Menu 676 directories. Those thermal imager functions that can be used to load Please note that a new sub-directory is created after IR images and photos, to make settings for contents and...
  • Page 63 Display Menus File Menu directory lists and file lists, use the joystick Enter button. photo shows (from irb or jpg file). If the thermal image A directory can be opened using the joystick Enter button saved as irb contains additional data, the left upper or navigating to the right.
  • Page 64 TiX620, TiX640, TiX660, TiX1000 Users Manual The  button can be used to highlight files and The file selected from the file list (highlighted blue) is directories. The  button can be used to delete files and displayed (large) by using the joystick Enter button. When directories.
  • Page 65: Save Submenu

    Display Menus File Menu The "Load Gallery" submenu function can be used to The "Saving format" menu item can be used to set the quickly find files from preview images. data and formats to be saved (see Saving Format Submenu on page 3-23). After the function is started, the directories are shown as index cards, the contents of which can be opened and Real-time saving...
  • Page 66 TiX620, TiX640, TiX660, TiX1000 Users Manual During real-time saving, only thermal images are stored in Video saving the irb format. This way, it is possible to subsequently edit You can do a non-radiometric video (as an alternative to and correct the digital data of the sequence using the real-time saving of the digital raw data), if: analysis software.
  • Page 67 Display Menus File Menu changed parameters (emissivity, ambient temperature, To start auto capture, the start time (date, time) and the transmission, path temperature) is possible, these saving interval and the number of IR images to be saved parameters should be set correctly before the recording must be defined initially.
  • Page 68: Ir Photonotes Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual There is a keyboard for entering alphanumeric characters, whereby this keyboard is shown by pushing the joystick Enter button in the text annotation line. The  keyboard can simply be navigated with the joystick Capital and lower-case letters are switched similarly to a computer keyboard.
  • Page 69: Format Sd Submenu

    Display Menus File Menu Format SD Submenu Saving Format Submenu If all data saved to the SDHC card is to be deleted, this Using the "Saving format" menu item, data to be saved in can be done by formatting the card. The corresponding addition to the thermal image and its format can be function must be started in the "Format SD"...
  • Page 70 TiX620, TiX640, TiX660, TiX1000 Users Manual Table 3-2 shows the selectable settings. Table 3-2. Setting Selections Setting Selection Format Digital image Saving the visual image synchronously with .irb−thermal image and photo in one file the thermal image .jpg−photo in separate file 1,024 x 720 8 MP (3,264 x 2,448) .irb −thermal image and audio in one file...
  • Page 71: Measure Menu

    Display Menus Measure Menu Measure Menu The "Measure" menu summarizes all temperature measurement functions. In order that measured values are displayed, the corresponding setting in the "Image elements" menu must be activated (see Elements Submenu on page 3-12). hvh183.jpg Spot Temperature Submenu It is possible to display the (global) temperature maximum and/or temperature minimum within the thermal image by selecting the options "Maximum"...
  • Page 72: Measurement Definitions Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual In order to create a new AOI, you must initially open the Measurement Definitions Submenu "Editor" submenu and select the required format of the The "Measurement definitions" menu item can be used to measuring object at "New".
  • Page 73 Display Menus Measure Menu A measuring point is initially created in the center of the Line L image and can be moved in the image area by using the The position of the measuring line can be defined by  joystick .
  • Page 74 TiX620, TiX640, TiX660, TiX1000 Users Manual hvh193.jpg hvh194.jpg hvh190.jpg hvh192.jpg Along with the option of deleting individual AOIs in the respective editor by using the  button, all created AOIs can be deleted simultaneously using the corresponding dialog to be confirmed:...
  • Page 75 Display Menus Measure Menu Rectangle R Polygon PG A rectangle selected in the "Editor" submenu in the "New" The thermal imager supports polygon planes with a menu item is initially displayed as a square in the center maximum of 11 points, the position of which can be of the image.
  • Page 76 TiX620, TiX640, TiX660, TiX1000 Users Manual hvh202.jpg hvh203.jpg hvh204.jpg hvh205.jp hvh206.jp hvh207.jpg 3-30...
  • Page 77: Correction Submenu

    Display Menus Measure Menu Correction Submenu Polyline PL In analogy to the polygon (plane), a line can also be The "Correction" menu item can be used to enter the created with a maximum of 11 support points: correction parameters emissivity and ambient temperature, as well as path temperature, relative humidity, transmission, and distance in accordance with the current measuring situation.
  • Page 78 TiX620, TiX640, TiX660, TiX1000 Users Manual The parameters emissivity and ambient temperature, as exact knowledge of the real properties of the measuring well as path temperature, relative humidity, transmission, object, as well as of the ambient conditions and the and distance allow for precise temperature measurement.
  • Page 79 Display Menus Measure Menu Note The thermal imager works with a wavelength μ μ range of 7.5 m to 14 m. The influence of the atmosphere on the measurement result can be neglected during the majority of the measurements in this range – therefore, the transmission is set to 1.00 at the factory.
  • Page 80 TiX620, TiX640, TiX660, TiX1000 Users Manual If the actual (lower) emissivity of the measured object is and can be determined easily. If the "Automatic" option is to be taken into consideration, it is absolutely necessary selected, the distance calculated from the process of to also determine the ambient temperature ("reflected...
  • Page 81: Gps Submenu

    When this function is activated, the yellow laser symbol When switching off the GPS receiver, the first information will be displayed in the tool bar below the Fluke logo line is hidden automatically. simultaneously with an acoustic signal (2x beep). The laser pointer, integrated depending on the equipment, is activated analogously.
  • Page 82: Settings Menu

    TiX620, TiX640, TiX660, TiX1000 Users Manual Calibration Submenu  Warning The thermal imager is calibrated to measure To prevent eye damage and personal injury: temperatures in the range of (-40…1,200) °C. Depending • on the equipment, the total measuring range and the Do not look into the laser.
  • Page 83: Extras Submenu

    When using the thermal imager for mobile The settings that can be selected in the "Extras" menu applications and when there is a constantly item activate the following functions: changing scene, Fluke recommends activating • Premium A camera-internal compensation (NUC) the automatic measuring range setting (factory setting).
  • Page 84: Automatic Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual case. To use the SuperResolution Automatic Submenu function, the thermography system must be positioned firmly (tripod) and this function is only suitable for measuring objects with a constant temperature. • DRE "Dynamic SuperResolution™" – In...
  • Page 85: Compensation Submenu

    Display Menus Settings Menu • Compensation Submenu Span "Auto Mode (Span)": with its upper and lower limits, the set representation To implement the specified measurement accuracy, the range follows the maximum und/or thermal imager does an internal compensation or NUC minimum temperature values of the (factory setting).
  • Page 86: Buttons Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual In the Shutter  Interval mode, the interval for an Buttons Submenu automatic compensation can be set. For this, the time The thermal imager can be adapted flexibly to different after which an automatic compensation is to be requirements by individually assigning functions to the performed must be entered in seconds.
  • Page 87 Display Menus Settings Menu Table 3-3 contains a summary of the different functions selectable for the different buttons. To identify the button function as set at the factory, the button symbols are assigned accordingly in the function column. Table 3-3. Button Functions Function Button Explanation...
  • Page 88 TiX620, TiX640, TiX660, TiX1000 Users Manual Table 3-3. Button Functions (cont.) Function Button Explanation Short/long (M: halfway/completely) Lang Max/Min menu  long For manually setting Maximum/Minimum Zoom menu For setting the zoom Isotherms menu For setting the isotherms Infrared/Digital image Switch-over image mode infrared image –...
  • Page 89: Digital Alarm Output Submenu

    Display Menus Settings Menu The functions can be set in the corresponding input field Digital Alarm Output Submenu for the respective button: The "Digital Alarm Output" menu item can be used to define conditions, the fulfillment of which will trigger the camera to perform actions.
  • Page 90: Configuration Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual Two temperature thresholds can be defined referring to Configuration Submenu the average value ("Average"), the maximum temperature You can save your individual device settings as device value ("Upper limit"), or the minimum temperature value configuration in the thermal imager.
  • Page 91 Display Menus Settings Menu hvh241.jpg hvh242.jpg hvh244.jpg hvh243.jpg 3-45...
  • Page 92: System Menu

    TiX620, TiX640, TiX660, TiX1000 Users Manual As an alternative to a configuration name generated System Menu automatically consisting of a date and a time, e.g. The "System" menu item contains the settings and cfg_20120622_1530, a name consisting of a maximum of information about the basic functions of the thermal 20 characters can be edited to save the configuration.
  • Page 93: Display Submenu

    "Bright", "Medium", After the system settings are made for your and "Dimmed". When the ambient lighting conditions are individual requirements, Fluke recommends "normal", the brightness setting "Medium" is absolutely saving the settings in a user configuration.
  • Page 94: Regional Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual Regional Submenu Date and Time Submenu The "Regional" submenu can be used to set the Setting the date and the time corresponds to the language, the date format, the date separator, and the procedure usual for PCs: we recommend entering the time format.
  • Page 95: Menu Layout Submenu

    Display Menus System Menu Menu Layout Submenu However, when navigating to the corresponding menu item, this menu item is displayed completely even when it The "Menu layout" submenu is used to make the settings exceeds the menu width. for the graphical user interface. The selection options for the font size comprise the 3 levels "Large", "Normal", and "Small".
  • Page 96: Menu Control Submenu

    TiX620, TiX640, TiX660, TiX1000 Users Manual Menu Control Submenu The way the navigation in the camera menu is controlled can also be adapted to individual requirements. For quick navigation, the experienced user can set submenus to drop down automatically when a menu item is selected.
  • Page 97: Maintenance

    Chapter 4 Maintenance  Caution Introduction When the lens is removed (lens change), the The possible maintenance work to be performed on the aperture of the camera housing must be thermal imager is limited to the process of cleaning outer protected against any kind of contact with surfaces.
  • Page 98: Calibration

    The manufacturer offers to take back the thermal imager product from the customer in order to ensure that the device is disposed of in an environmentally friendly manner when it is at the end of its use. In this case, see How to Contact Fluke for more information.
  • Page 99: Battery

    If correct to prevent battery leakage. exposure to chemicals occurs, clean with water and get medical aid. • Use only Fluke approved power adapters to charge the battery. • Do not disassemble the battery. •...

This manual is also suitable for:

Tix640Tix620Tix1000Tix660-60Tix640-60Tix620-30

Table of Contents