Digital Inputs; Digital Outputs; Table 5-1: Pin Assignment For Din Connector; Figure 5-6: Wiring The Digital Input (Example) - Fluke ThermoView TV30 Series User Manual

Thermal imager camera
Table of Contents

Advertisement

®
ThermoView
TV30 Series
Users Manual, Rev. 1.0, May 2023

5.7.2 Digital Inputs

The TV30 SA camera provides 3 digital inputs which can be used as switch to initiate different tasks, see section
7.4.1
<I/O>
<Internal>, page 48.
A high signal requires voltages of 4.5 - 24 V. A low signal is detected for voltages below 2 V.
The digital inputs are galvanically isolated from GND power and housing ground but not from each other

5.7.3 Digital Outputs

The TV30 SA camera provides 3 digital outputs which can be used to indicate different tasks, see section
7.4.1
<I/O>
<Internal>, page 48.
The signal output can be done in a specific mode. The desired mode can be set via the user and always applies
to all outputs. The following modes are available:
Pull-Up – the pull-up resistor is provided internally. The logical high level is fixed to +5 VDC.
Open-Drain – requires the provision of an external pull-up resistor and a voltage supply. The logical high
level is determined by the external voltage supply and not limited to +5 VDC.
30

Table 5-1: Pin Assignment for DIN Connector

Connector Pin
TV30 SA
M
+ 24 VDC
L
GND Power
D
Input 1
F
Input 2
B
Input 3
C
GND Input
J
Output 1
H
Output 2
G
Output 3
K
GND Output
A
n.a.
E
Shield

Figure 5-6: Wiring the Digital Input (Example)